E-Stop Inputs
0: All E-Stops are closed.
1: E-Stop 1 is open.
2: E-Stop 2 is open.
3: E-Stop 3 is open.
4: E-Stop 4 is open.
5: E-Stop 5 is open.
6: E-Stop 6 is open.
7: E-Stop 7 is open.
8: E-Stop 8 is open.
9: E-Stop 9 is open.
10: E-Stop 10 is open.
11: E-Stop 1A is open, 1B is short.
12: E-Stop 1A is short, 1B is open.
13: E-Stop 2A is open, 2B is short.
14: E-Stop 2A is short, 2B is open.
15: E-Stop 3A is open, 3B is short.
16: E-Stop 3A is short, 3B is open.
17: E-Stop 4A is open, 4B is short.
18: E-Stop 4A is short, 4B is open.
19: E-Stop 5A is open, 5B is short.
20: E-Stop 5A is short, 5B is open.
21: E-Stop 6A is open, 6B is short.
22: E-Stop 6A is short, 6B is open.
23: E-Stop 7A is open, 7B is short.
24: E-Stop 7A is short, 7B is open.
25: E-Stop 8A is open, 8B is short.
26: E-Stop 8A is short, 8B is open.
27: E-Stop 9A is open, 9B is short.
28: E-Stop 9A is short, 9B is open.
29: E-Stop 10A is open, 10B is short.
30: E-Stop 10A is short, 10B is open.
31: E-Stop status is unknown.
Operating Mode
0: Power-Up
1: OK (Go)
2: Stop Condition
3: Fault
4: Operating mode is unknown.
Reset Mode Invalid
0: The reset mode is known.
1: The reset mode is unknown.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
E-Stop Safety Module –
Reset Mode
0: The reset mode is manual.
1: The reset mode is automatic.
Reset Input Invalid
0: The status of the reset input is known.
1: The status of the reset input is
unknown/disabled.
Reset Input
0: The reset input is open.
1: The reset input is closed.
K1 Relay Invalid
0: The state of the K1 relay is known.
1: The state of the K1 relay is unknown.
K1 Relay State
0: The K1 relay is OFF.
1: The K1 relay is ON.
K2 Relay Invalid
0: The state of the K2 relay is known.
1: The state of the K2 relay is unknown.
K2 Relay State
0: The K1 relay is OFF.
1: The K1 relay is ON.
Autobaud
0: Autobaud is OFF.
1: Autobaud is ON.
Monitor Input Invalid
0: The Monitor input status is known.
1: The Monitor input status is unknown.
Monitor Input 1
0: Monitor input 1 is open.
1: Monitor input 1 is closed.
Monitor Input 2
0: Monitor input 2 is open.
1: Monitor input 2 is closed.
Monitor Input 3
0: Monitor input 3 is open.
1: Monitor input 3 is closed.
Monitor Input 4
0: Monitor input 4 is open.
1: Monitor input 4 is closed.
8.5 Additional Information Available through Explicit Messaging
Autobaud Setting:
1 byte message, 0 = OFF, 1 = ON. See EDS file for path information.
Factory setting is ON.
Diagnostic Information:
See EDS file for details regarding Fault Type and Troubleshooting suggestion information.
Model ES-TA-3F1
Fault Type
0: No Fault
1: E-Stop 1 Fault
2: E-Stop 2 Fault
3: E-Stop 3 Fault
4: E-Stop 4 Fault
5: E-Stop 5 Fault
6: E-Stop 6 Fault
7: E-Stop 7 Fault
8: E-Stop 8 Fault
9: E-Stop 9 Fault
10: E-Stop 10 Fault
11: Reset Input Fault
12: Monitor 1 Fault
13: Monitor 2 Fault
14: Reserved
15: Monitor 3 Fault
16: Reserved
17: Reserved
18: Reserved
19: Monitor 4 Fault
20: Reserved
21: Reserved
22: Reserved
23: Reserved
24: Reserved
25: Reserved
26: Reserved
27: Output Fault
28: Power Fault
29: Auto Reset Fault
30: The Fault type is unknown