Section 8 Devicenet - Banner ES-TA-3F1 Operating Instructions Manual

Ten-input emergency stop safety module with devicene
Table of Contents

Advertisement

WARNING . . .
!
For Information
Monitoring Only
NEVER use the DeviceNet
data to control a safety-related function.
DeviceNet
information must be used for
non-safety monitoring purposes, only. To
do so creates an unsafe condition which
could lead to serious injury or death.
Power Requirements
Bus Status Indicator
Vendor Code
Device Type
Connection Types Supported
Product Code
Network Address
Baud Rate Supported
EDS File Part Number
EDS File Name
Bit Map Icon File Name
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
E-Stop Safety Module –
SECTION 8 – DeviceNet
8.1 Information Communicated to DeviceNet
Module Status
E-Stop Inputs Status
Monitor Inputs Status
Reset Mode
Reset Input Status
Output Module Status
Diagnostic Information Fault Type
Autobaud
* Factory setting
8.2 DeviceNet Specifications
11 to 25V dc; 80 mA (supplied by DeviceNet network)
A bi-colored (red/green) LED visible on the control module indicates network status:
Green
Red
Green/Red
Green/Red/OFF
12 (Banner Engineering Corp.)
131 (E-Stop Safety Module)
Explicit Message, Poll, COS (Change of State)
1 (10-Input E-Stop Module)
0-63 (Manual switches or Network configured)
Autobaud or Network configured (125K, 250K, 500K)
Factory setting is Autobaud ON.
52243
131_1_1.eds
131.bmp
OK (GO)
Power-Up
Stop Condition
Fault
All Closed
E-Stop X Open (Where X is 1, 2, 3, 4, 5, 6, 7, 8, 9 or 10. Only
one open input is reported at a time.)
Fault (Input number and status of both circuits for that input;
i.e., 1A Open, 1B short)
All Closed
Monitor X Open (Where X is 1, 2, 3, or 4. Only one open
input is reported at a time.)
Auto Reset or Manual Reset*
Open, Closed or Disabled (Reset Input is disabled in Auto
Reset mode)
K1 Energized or De-energized
K2 Energized or De-energized
Troubleshooting Suggestions
ON* or OFF
Steady
On line, connected/allocated to master
Flashing
On line, not connected/allocated to master; if Autobaud is
ON, address and baud rate ok
Steady
Critical network fault or duplicate node address detected
Flashing
Connection timeout or no power to light screen
OFF
No network power or off line
Flashing
Autobaud detecting network baud rate
Sequentially
NOTE: EDS and Bitmap files on 3.5" floppy disk supplied with
controller (part number 52243). For custom EDS files or Bitmap
files contact Banner Applications Department