Technical Data - Graco ProMix 2KE Operation

Pump-based plural component proportioner
Hide thumbs Also See for ProMix 2KE:
Table of Contents

Advertisement

Technical Data

Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . See Models, page 3.
Maximum working air pressure . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 - 100 psi (0.5 - 0.7 MPa, 5.2 - 7 bar)
Air filter inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8 npt(f)
Air filtration for air logic (Graco-supplied). . . . . . . . . . . . .' 5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied) . . . . . . . . . . 30 micron (minimum) filtration required; clean and dry air
Mixing ratio range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1:1- 30:1
On-ratio accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to + 1%, user selectable
Fluids handled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . one or two component:
Viscosity range of fluid. . . . . . . . . . . . . . . . . . . . . . . . . . . 20- 5000 cps*
Fluid filtration (user-supplied) . . . . . . . . . . . . . . . . . . . . . 100 mesh minimum
Fluid outlet size (static mixer) . . . . . . . . . . . . . . . . . . . . . 1/4 npt(f)
External Power Supply Requirements . . . . . . . . . . . . . . . 85 - 250 Vac, 50/60 Hz, 2 amps maximum draw
Operating temperature range . . . . . . . . . . . . . . . . . . . . . 41- 122° F (5-50° C)
Approximate Weight
Environmental Conditions Rating . . . . . . . . . . . . . . . . . . indoor use, pollution degree (2), installation category II
Noise Level
Sound pressure level. . . . . . . . . . . . . . . . . . . . . . . . .
Sound power level . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303, 304 SST, Tungsten carbide (with nickel binder),
3A0868A
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
• moisture sensitive isocyanates
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
300 lb (136 kg)
below 70 dBA
below 85 dBA
perfluoroelastomer; PTFE
Technical Data
59

Advertisement

Table of Contents
loading

Table of Contents