Configure 1-4 (Screens 18-21) - Graco ProMix 2KE Operation

Pump-based plural component proportioner
Hide thumbs Also See for ProMix 2KE:
Table of Contents

Advertisement

Setup Mode Details

Configure 1-4 (Screens 18-21)

Configure 1 (Screen 18) displays if
Setup Home (Screen 17). This screen allows users to
set up the system type (pump or meter) and number of
guns (1 or 2). If 1 gun is selected, users can enable a
gun flush box (✓=yes; X=no). For all pump systems, the
type of dosing is dynamic, and the number of colors is 1.
See Dynamic Dosing, page 36, for more information.
System
type
F
. 29. Configure 1 (Screen 18)
IG
Press
to highlight the desired field. Press
to display the dropdown menu for that field.
Press
to choose from the menu options and
to set. Press
Press
to move through Configure 2 (Screen
19), Configure 3 (Screen 20), and Configure 4
(Screen 21).
NOTE: If you change system type (pump to meter) or
number of guns, a verification screen appears. Use
to highlight and press
change, or on the
to return to Configure 1 (Screen
18) without making a change. If a change is made, the
system locks so that you cannot spray or mix. Power
down and power back up again to clear the lock and put
the new settings into effect. The lock ensures that the
selection was intended, and prevents the user from
attempting to operate with incorrect settings.
Configure 2 (Screen 19) allows users to set for each gun
the hose length and hose diameter. The system uses
this information to calculate pot life.
32
is selected on
Gun flush
box
Number
of guns
Home
to move to the next field.
on the
to make the
Gun 1 hose
length
Gun 1 hose
diameter
F
. 30. Configure 2 (Screen 19)
IG
Configure 3 (Screen 20) allows users to set preferred
language (for optional USB Module), date format, date,
time, password, and number of minutes of inactivity
required before the backlight turns off. Configure 4
(Screen 21) allows users to set preferred units for dis-
tance, volume, and pressure.
Date
format
Date
Time
Configure 3
Pressure
units
Configure 4
F
. 31. Configure 3 (Screen 20) and Configure 4
IG
(Screen 21)
Gun 2 hose
length
Gun 2 hose
diameter
Home
USB log
language
Password
Backlight
timer
Distance
units
Volume
units
Home
3A0868A

Advertisement

Table of Contents
loading