Pump Calibration
Calibrate the pump:
•
The first time the system is operated.
•
Whenever new materials are used in the system,
especially if the materials have viscosities that differ
significantly.
•
At least once per month as part of regular mainte-
nance.
•
Whenever a pump is serviced or replaced.
NOTE:
•
Pump factors on Calibration 1 (Screen 22) are
updated automatically after the calibration pro-
cedure is completed. You also may manually
edit them if desired.
•
All values on this screen are in cc or cc/in., inde-
pendent of the units set in Configure 4 (Screen
21).
1. Before calibrating pump A or B, prime the system
with material. See Prime the System, page 26.
2. On the Display Module, press
screens.
3. Press
to display Calibrate 1 (Screen 22).
K-factors are shown for Pump A and Pump B.
4. Press
to move to Calibration 2 (Screen 23).
5. Press
to highlight the pump you wish to cali-
brate. An X displays in the box. Press
6. Press
to start the calibration on the highlighted
pump (A or B). Press
7. Trigger gun into a graduated cylinder. Dispense
about 200-300cc of material.
3A0868A
to access setup
.
to cancel the calibration.
NOTE: Stop triggering the gun when desired amount is
reached. Do not press
tion.
8. The volume that the ProMix measured displays on
the Display Module.
F
. 45. Dispensed Volume Comparison
IG
9. Compare the amount on the Display Module to the
amount in the graduated cylinder.
NOTE: For maximum accuracy, use a gravimetric
(mass) method to determine the actual volumes dis-
pensed.
10. If the screen and actual volumes are different, enter
the actual dispensed volume in cc for the A or B
field, and press
If the value was substantially different, repeat the
calibration process.
11. After the volume for A or B is entered, the ProMix
2KE controller calculates the new pump factor and
shows it on Calibration 1 (Screen 22) and Calibra-
tion 2 (Screen 23).
12. Before you begin production, clear the system of
solvent and prime it with material.
a. Go to Mix mode.
b. Trigger the gun into a grounded metal pail until
mixed material flows from the gun nozzle.
c. To begin operation, see Spraying, page 27.
Pump Calibration
, as it will cancel the calibra-
Volume measured
by system displays
here.
Enter dispensed
volume here.
.
41