Prime The System - Graco ProMix 2KE Operation

Pump-based plural component proportioner
Hide thumbs Also See for ProMix 2KE:
Table of Contents

Advertisement

Basic Operation

Prime the System

1. Adjust the main air pressure. Most applications
require about 80 psi (552 kPa, 5.5 bar) air pressure
to operate properly. Do not use less than 75 psi (517
kPa, 5.2 bar).
2. From Run Home (Screen 1), press
sure that the system is in Standby mode.
3. Press
to show the drop-down menu.
4. Press
to highlight Pump A, then press
5. Put Pump A into supply pail.
6. Adjust component A supply pressure as
needed for your application. Use lowest
pressure possible.
NOTE: Do not exceed the maximum rated working pres-
sure shown on the system identification label or the low-
est rated component in the system.
26
. Make
Standby
.
7. Open the fluid supply valve to the
pump.
8. If using an electrostatic gun, shut
off the electrostatics before flushing
the gun.
9. If using a gun flush box, place the gun in the box
and close the lid. Press
cycles.
If the gun flush box is not used, trig-
ger the gun into a grounded metal
pail until the system returns to
Standby.
10. Press
to stop the pump before 12 cycles are
completed. If the pump is not fully primed after 12
cycles, press
again.
11. Repeat for Pump B.
. The pump will run 12
3A0868A