Balancing A/B Pressure
If component B pressure is too high, it will push the com-
ponent A stream aside during B injection. The valve will
not open long enough, causing a High Ratio alarm.
If component B pressure is too low, it will not be injected
in sufficient volume. The valve will stay open too long,
causing a Low Ratio alarm.
Selecting the correct component B restrictor size and
balancing the A/B pressures will keep the system in the
proper pressure range, resulting in a consistent mix
ratio.
F
. 42 shows the A to B pressure balance, read at the
IG
proportioner inlet. It is recommended that the compo-
nent B pressure be 5-15% higher than the component A
pressure to keep the system in the control range, hold
the proper mix ratio, and obtain properly mixed material.
If pressures are not balanced ("B Pressure Too High" or
"B Pressure Too Low"), it may not be possible to hold the
desired mix ratio. The system will generate an off ratio
alarm and stop operation.
NOTE: In multi-flow rate systems, it is recommended
that you set up the system to run properly at the highest
flow rate, to ensure adequate fluid supply across the
flow rate range.
In dynamic dosing, component A dose valve is con-
stantly on. Component B dose valve will cycle on and
off; one cycle every 0.5 – 1.0 seconds indicates proper
balance.
Monitor system performance by watching the pressure
readings for each pump on Run Pump Control (Screen
15).
F
. 41. Monitor Pump Pressures
IG
Warning messages also provide information on system
performance. Adjust pressures accordingly. See Table 3
on page 38.
3A0868A
B Pressure
Too High
A Pressure
F
. 42. A/B Control Range with Properly Sized
IG
Restrictor
B Pressure
Too High
A Pressure
NOTE: If the restrictor is too small, it may be
necessary to supply more differential pressure
than is available in your system.
F
. 43. A/B Control Range with Too Large a
IG
Restrictor
Setup Mode Details
B Pressure
Too Low
B Pressure
B Pressure
Too Low
B Pressure
37