Download Print this page

Quantum StorNext QM1200 Replacing Manual page 4

Base system, a controller battery
Hide thumbs Also See for StorNext QM1200:

Advertisement

StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery
2.
Refer to
Figure 1 Controller Location
3.
Refer to
If a battery fault is detected, the amber Battery Service Action Required LED is on.
Figure 2 Battery Service Action Required LED on the Controller
Removing the Controller from the Array
1.
Label each copper cable or fiber-optic cable that is attached to the controller canister with the failed battery so
that you can reconnect each cable correctly after the controller canister is reinstalled.
2.
Record the information from the seven-segment display on the base system.
The display flashes a sequence of codes. To find information about the displayed diagnostic codes, refer to
StorNext Q-Series Storage Install Guide.
Use either the GUI (first bullet) or the CLI (second bullet) to take the appropriate controller offline.
From the Hardware pane in the Array Management Window, right-click the picture of the controller that you
want to take offline, and select Advanced >> Place >> Offline.
Figure 1
to locate the controllers within the array (representative array provided).
1.
Controller Canister A
2.
Drive Expansion
3.
Controller Canister B
4.
Drive Expansion
Figure 2
to locate the controller with a battery fault.
1.
Battery Service Action Required LED (Amber)
ATTENTION Potential degraded performance – To prevent degraded performance, do not twist, fold,
pinch, or step on the cables. Many cables have a minimum bending radius. For example, do not bend
fiber-optic cables tighter than a 5-cm (2-in.) radius. Check the specifications for your cables, and do not
bend any cable tighter than the minimum specified radius.
Quantum Corporation
- 2 -
April 2015

Advertisement

loading

This manual is also suitable for:

Stornext qs2400Stornext qs1200