Download Print this page

Quantum StorNext QM1200 Replacing Manual

Base system, a controller battery
Hide thumbs Also See for StorNext QM1200:

Advertisement

Quick Links

StorNext QM1200, QS1200 or QS2400 Base System
Replacing a Controller Battery
*6-68009-01 B*
6-68009-01 Rev B

Advertisement

loading

Summary of Contents for Quantum StorNext QM1200

  • Page 1 StorNext QM1200, QS1200 or QS2400 Base System Replacing a Controller Battery *6-68009-01 B* 6-68009-01 Rev B...
  • Page 2 Quantum Corporation is prohibited by law and constitutes a punishable violation of the law. TRADEMARK STATEMENT Quantum, the Quantum Logo, Backup. Recovery. Archive. It's What We Do., Be Certain, Be Quantum Certain, DLT, the DLT Logo, DLTSage, DLTtape, the DLTtape Logo, DXi, DXi Accent, Dynamic Powerdown, FastSense, FlexLink, GoProtect, GoVault, iLayer, Lattus, MediaShield, Optyon, Pocket-sized., Well-armored., Preserving the World's Most Important Data.
  • Page 3 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Replacing a Controller Battery in the StorNext QM1200, QS1200 or QS2400 Base System You can determine whether you have a failed controller battery in two ways: The Recovery Guru directs you to replace a failed controller battery.
  • Page 4 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Refer to Figure 1 to locate the controllers within the array (representative array provided). Figure 1 Controller Location Controller Canister A Drive Expansion Controller Canister B...
  • Page 5 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Run the following command: — SMcli <DNS-network-name-or-IP-address> -c “set controller [(a | b)] availability=offline”; If necessary, wait for the Controller Service Action Allowed LED to come on. This indication might take several minutes for a large configuration.
  • Page 6 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Figure 4 Controller Air Blocker Remove the controller canister (Figure 5) that has the failed controller battery. Unlock the release levers, and pull the release lever outward to release the controller canister.
  • Page 7 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Set the controller canister on a flat, static-free surface, with the release lever up. ATTENTION Possible equipment damage – The controller slot cannot remain open for more than three minutes because of the possibility of overheating the equipment.
  • Page 8 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Replacing the Battery in the Controller Press down on both of the top cover latch buttons (Figure 7), and slide the top cover to the rear of the controller canister.
  • Page 9 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Move the locking handle down to pull the failed controller battery out of the controller canister (Figure Figure 8 Battery and Locking Handle in the Controller...
  • Page 10 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Reinstall the top cover on the controller canister by sliding the top cover forward until the top cover latch buttons click. Reinstalling the Controller into the Array Remove the controller air blocker from the controller slot.
  • Page 11 StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller Battery April 2015 Did this action correct the problem? Yes – Go to step 7. — No – If the problem is not resolved, contact your Customer and Technical Support representative.

This manual is also suitable for:

Stornext qs2400Stornext qs1200