Parameter list - inverter information (selection)
Parameter
Display of current messages on the actual
operating status of the variable frequency drive
such as faults, warnings or the cause of a switch-
P700
on block.
Current operating
Selection:
status
Current fault (P700, [-01])
Current warning (P700, [-02])
Reason for switch-on block (P700), [-03])
Displays the last 5 variable frequency drive faults.
Selection:
P701
Last fault (P701), [-01])
Last error
Penultimate fault (P701, [-02])
Displays the firmware version/Inverter revision
Selection:
P707
Software version (P707, [-01])
Software version
Revision (P707, [-02])
P708
Shows the switching status of the digital inputs.
Status of digital
input
Displays the measured analog input value.
Input selection:
Potentiometer P1 (P400, [-01]) - SK 2x5E
P709
Potentiometer P2 (P400, [-02]) - SK 2x5E
Voltage of analog
AIN1 (P400, [-01]) - SK 2x0E
input
AIN2 (P400, [-02]) - SK 2x0E
DIN 2 (P400, [-06])
DIN 3 (P400, [-07])
P719
Displays the actual output current.
Actual current
P740
Displays the actual control word and the setpoints.
Process data bus
in
P749
Displays the actual DIP switch setting (S1).
State of DIP
switch
Pos : 631 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/_M eldungen z um Betri ebszus tand_01 (Übersc hrift + Inhalt) [SK xxxE] @ 3\mod_1361795506047_14638.doc x @ 59690 @ 1555 @ 1
BU 0240 en-US-3118
Description
5 Parameter
Settings/functions (selection)
Error group:
1 / 2 = inverter/motor overtemperature
3 / 4 = overcurrent fault
5
= overvoltage fault
16
= phase monitoring motor
19...= error in parameter identification
See P700
Bit 0 = DIN 1
Bit 1 = DIN 2
...
[-01] = STW (source P509)
[-02...-04] SW 1...3 (source P510[-01]
[-11...-13] SW 1...3 (source P510[-02]
Bit 0 = DIP switch 1
Bit 1 = DIP switch 2
...
73