Triton Spellbind Installation And Operating Instructions Manual page 29

Thermostatic electric shower
Table of Contents

Advertisement

Problem/Symptom
7 Water continues
to flow when unit is
isolated at isolating
switch.
8 Pressure relief device
has operated (water
ejected from PRD
tube).
Spellbind
FAULT FINDING
Cause
7.1 Debris in solenoid.
8.1 Blocked
showerhead.
8.2 Twisted/blocked
flexible shower hose.
8.3 Showerhead
not removed whilst
commissioning.
Action/Cure
7.1.1 Contact Customer Service for advice.
8.1.1 Clean or replace blocked showerhead
cartridge and then fit a new PRD.
8.2.1 Check for free passage through hose.
Replace the hose if necessary, then fit new PRD.
8.3.1 Fit new PRD. Commission unit with
showerhead removed.
27