PRIMING THE MIX PUMP
Tank filling:
Take 1 bag of mix from the refrigerator.
Pour one bag of mix into the each tank allowing it to drain into the freezing cylinders.
Lower the distribution handles and wait till only full strength mix(not mix and sanitizer) will
come out from front lid; close the handles.
Connecting the mix pressure pipe:
Keep on pouring the mix and wait till the cylinders have been completely filled(during that
time you see bubbles in the tanks); with sanitized hand, draw compression pipe out from
the sanitizing solution and insert them into relevant tank bottoms.
With sanitized hands, take the connection pipes( ) from the sanitizing solution and
insert them well into the compression pipes( ), then into the pumps and lock them. Mix
inside the tanks shall never reach the pump(see the picture); furthermore mix shall be added
whenever level is 2 cm from bottom.
Place tank covers back.
Select the function Production and after a few minutes, ice cream is ready for distribution.
TROUBLESHOOT GUIDE
IRREGULARITY
Low ice cream overrun
Drip drawer shows mix drops
30
CAUSE
1.Pump stuffing box not properly
installed or damaged
1. Pump stuffing box not properly
installed
PROCEDURE TO FOLLOW
1. Change regulator( )
1. Stop the machine, disassemble
pump and check thir stuffing
boxes are o.k