Ams Distance Measurement Device, Odsl Xx Optical Distance Sensors; With Rs 232 Interface (S4 Switch Position B) - Leuze electronic MA 208i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on ethernet tcp/ip
Table of Contents

Advertisement

16.12 AMS distance measurement device, ODSL xx optical distance sensors 

with RS 232 interface (S4 switch position B)

Notice!
In this switch position, 6-byte data (fixed) is always expected by the device. This is why a
quick telegram sequence can be transmitted reliably even without a data frame.
AMS
Specifications for the serial interface
Default parameter
Baud rate
Data mode
Handshake
Protocol
Frame
Specifications for Command mode
To activate the Command mode, bit 0 must be set to 1 in control byte 0.
For further information, see chapter 11.1.2 "Command mode", figure 11.1.
Control bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Recommended settings
Setting the data length is not required.
Leuze electronic
AMS
38400
8N1
no
binary protocol without acknowledgment
<Data>
Meaning
Transmit individual position value = single shot
Cyclically transmit position values
Stop cyclical transmission
Laser diode on
Laser diode off
Transmit single speed value
Cyclically transmit speed values
Specifications for Leuze end devices
MA
208i
Corresponds to
serial command
(HEX)
C0F131
C0F232
C0F333
C0F434
C0F535
C0F636
C0F737
79

Advertisement

Table of Contents
loading

Table of Contents