Ethernet Wiring; Cable Lengths And Shielding - Leuze electronic MA 208i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on ethernet tcp/ip
Table of Contents

Advertisement

7.6

Ethernet wiring

A Cat. 5 Ethernet cable should be used for wiring.
For the connection technology transition from M 12 to RJ45, a "KDS ET M12 / RJ 45 W - 4P"
adapter is available that lets you connect standard network cables.
If no standard network cables are to be used (e.g., due to lacking IP... protection class),
you can use the "KB ET - ... - SA" user-configurable cables on the side of the MA 208i, see
table 14.4 Bus connection cable for the MA 208ion page 64.
The individual MA
"KB ET - ... - SSA" cable, see "Bus connection cable for the MA 208i" on page 64.
For unavailable cable lengths, you can configure your cables yourself. When doing so, make
certain that you connect TD+ on the M 12 connector with RD+ on the RJ-45 connector and
TD- on the M 12 connector with RD- on the RJ-45 connector, respectively, etc.
Notice!
Use the recommended connectors / sockets or the ready-made cables (see chapter 14 "Type
overview and accessories").
For further information on the topologies, see chapter 4.5.1 "Ethernet".
7.7

Cable lengths and shielding

 Observe the following maximum cable lengths and shielding types:
Connection
MA 208 – – Service
MA 208 – Host
Network from the first
MA 208 to the last
MA 208
MA 208 – Power 
supply unit
Switching input
Switching output
Table 7.5:
Leuze electronic
devices in a linear topology are connected with the 
208i
Interface
RS 232
Ethernet
Ethernet
Cable lengths and shielding
MA
Max. cable length
10 m
100 m
the maximum segment length
must not exceed 100 m for
100Base-TX Twisted Pair
(min. Cat. 5)
30 m
10 m
10 m
208i
Electrical connection
Shielding
not necessary
absolutely required, shielded
absolutely required, shielded
not necessary
not necessary
not necessary
33