Fast commissioning / operating principle

3
Fast commissioning / operating principle
Notice!
Below you will find a short description for the initial commissioning of the Ethernet
gateway MA 208i. Detailed explanations for the listed points can be found throughout the
handbook.
3.1

Mounting

The gateway mounting plate MA
• using four threaded holes (M 6) or
• using two M8x6 screws on the two lateral grooves.
3.2

Device arrangement and selection of the mounting location

Ideally, the MA
in order to ensure good operability, e.g., for configuring the connected device.
Detailed information can be found in chapter 6.3.1.
3.3

Electrical connection

The devices from the MA
differently depending on the interface.
The voltage supply (PWR IN) as well as the switching inputs/outputs (PWR OUT or PWR IN)
are connected there. The number and function of the switching inputs/outputs is dependent
on the connected end device.
An internal RS 232 interface is used for connecting the respective Leuze device. Another
internal RS 232 interface functions as a service interface for configuring the connected
device via a serial null modem cable.
PWR IN
SWIO_2
2
GND
3
5
4
FE
SWIO_1
M 12 connector
(A-coded)
Figure 3.1:
Detailed information can be found in chapter 7.
10
208i
should be mounted so that it is easily accessible near the Ident device
2xxi
family feature four M 12 connectors/sockets which are coded
PWR OUT
SWIO_2
2
VIN
VOUT 1
1
5
4
SWIO_1
M 12 socket
(A-coded)
MA 208 connections
208i
can be mounted in two different ways:
LEUZE Device
GND
3
FE
MA
208i
HOST / BUS IN
RD+
2
TD+ 1
TD-
3
4
RD-
M 12 socket
(D-coded)
Leuze electronic
BUS OUT
RD+
2
TD+ 1
TD-
3
4
RD-
M 12 socket
(D-coded)