Electrical connection
Ethernet TCP/IP cable assignments
MA 208 HOST / BUS IN
RD+
TD+ 1
Figure 7.3:
Notice for connecting the Ethernet TCP/IP interface!
Ensure adequate shielding. The entire connection cable must be shielded and earthed. The
RD+/RD- and TD+/TD- wires must be stranded in pairs.
Use CAT 5 cable for the connection.
7.4

BUS OUT

To set up an Ethernet network with other participants with linear topology, the MA
makes available another Ethernet interface. The use of this interface drastically reduces the
cabling requirements, as only the first MA
via which it can communicate with the host. All other MA
the first MA 208i,(see figure 4.5 on page 19).
TD+ 1
M 12 socket
Table 7.4:
 For the host connection of the MA 208i, the "KB ET - ... - SSA" ready-made cables are
preferred, see table 14.4 Bus connection cable for the MA 208ion page 64.
If you use user-configurable cables, note the following:
30
2
TD-
3
4
RD-
HOST/BUS IN cable assignments on RJ-45 (shown here is the device connection)
BUS OUT (4-pin socket, D-coded)
BUS OUT
RD+
2
TD-
3
4
RD-
(D-coded)
Pin assignment HOST/BUS OUT
Twisted pair
TD+ (1)
TD- (2)
Twisted pair
208i
requires a direct connection to the switch,
Pin
Name
1
TD+
2
RD+
3
TD-
4
RD-
Thread
FE
MA
208i
RJ 45
RD+ (3)
RD- (6)
208i
are connected in series to
Remark
Transmit Data +
Receive Data +
Transmit Data -
Receive Data -
Functional earth (housing)
Leuze electronic