Electrical Connection; Pwr In - Voltage Supply / Switching Input/Output - Leuze electronic MA 208i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on ethernet tcp/ip
Table of Contents

Advertisement

7.2

Electrical connection

The MA
208i
The voltage supply (PWR IN) as well as the switching inputs/outputs (PWR OUT or PWR IN)
are connected there. The number and function of the switching inputs/outputs is dependent
on the connected end device. Two additional M 12 sockets are used for connection to the
fieldbus. Both of these connections are D-coded.
An internal RS 232 interface is used for connecting the respective Leuze device. Another
internal RS 232 interface functions as a service interface for configuring the connected
device via a serial null modem cable.
PWR IN
SWIO_2
2
GND
3
1
5
4
FE
SWIO_1
M 12 connector
(A-coded)
Figure 7.2:
Described in detail in the following are the individual connections and pin assignments.
Attention!
Voltage supply and bus cable are coded in the same way. Please observe the printed con-
nection designations
7.2.1
PWR IN – voltage supply / switching input/output
PWR IN
SWIO_2
GND
3
FE
SWIO_1
M 12 connector
(A-coded)
Table 7.1:
Leuze electronic
features two M 12 connectors/sockets for voltage supply; each is A-coded.
PWR OUT
SWIO_2
2
VIN
VOUT 1
3
5
4
FE
SWIO_1
M 12 socket
(A-coded)
MA 208 connections
PWR IN (5-pin connector, A-coded)
Pin
1
2
2
3
VIN
1
5
4
4
5
Thread
PWR IN pin assignment
LEUZE Device
GND
Name
VIN
Positive supply voltage +18 ... +30 V DC
SWIO_2
GND
SWIO_1
FE
FE
MA
208i
Electrical connection
HOST / BUS IN
RD+
2
TD+ 1
TD-
3
4
RD-
M 12 socket
(D-coded)
Remark
Switching input/switching output 2
Negative supply voltage 0 V DC
Switching input/switching output 1
Functional earth
Functional earth (housing)
BUS OUT
RD+
2
TD+ 1
TD-
3
4
RD-
M 12 socket
(D-coded)
27

Advertisement

Table of Contents
loading

Table of Contents