Pwr Out Switching Input/Output; Bus In - Leuze electronic MA 208i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on ethernet tcp/ip
Table of Contents

Advertisement

7.2.2

PWR OUT switching input/output

PWR OUT
SWIO_2
VOUT 1
SWIO_1
M 12 socket
(A-coded)
Table 7.2:
Notice!
The maximum admissible current of the PWR OUT and IN connectors is maximum 3 A. To
be subtracted from this is the current consumption of both the MA and of the connected
end device.
The function of the switching inputs and outputs is dependent on the connected Leuze device.
Detailed information on this topic can be found in the respective operating instructions.
On delivery, the SWIO 1/2 are connected in parallel on PWR IN/OUT. This connection can
be separated with a jumper.
7.3

BUS IN

The MA
208i
HOST / BUS IN
TD+ 1
M 12 socket
Table 7.3:
 For the host connection of the MA 208i, the "KB ET - ... - SA-RJ45" ready-made cables
are preferred, see table 14.4 Bus connection cable for the MA 208ion page 64.
Leuze electronic
PWR OUT (5-pin socket, A-coded)
Pin
2
GND
3
5
4
FE
Thread
PWR OUT pin assignment
makes an Ethernet interface available as host interface.
RD+
2
TD-
3
4
RD-
(D-coded)
Pin assignment HOST / BUS IN
Name
1
VOUT
2
SWIO_2
3
GND
4
SWIO_1
5
FE
FE
BUS IN (4-pin socket, D-coded)
Pin
Name
1
TD+
2
RD+
3
TD-
4
RD-
Thread
FE
MA
208i
Electrical connection
Remark
Voltage supply for additional devices
(VOUT identical to VIN at PWR IN)
Switching input/switching output 2
GND
Switching input/switching output 1
Functional earth
Functional earth (housing)
Remark
Transmit Data +
Receive Data +
Transmit Data -
Receive Data -
Functional earth (housing)
29

Advertisement

Table of Contents
loading