Bar Code Reader Bcl 8 (S4 Switch Position 1) - Leuze electronic MA 208i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on ethernet tcp/ip
Table of Contents

Advertisement

16.2

Bar code reader BCL 8 (S4 switch position 1)

Specifications for the serial interface
Default parameter
Baud rate
Data mode
Handshake
Protocol
Frame
Specifications for Command mode
To activate the Command mode, bit 0 must be set to 1 in control byte 0.
For further information, see chapter 11.1.2 "Command mode", figure 11.1.
Control bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Recommended settings
Setting the data length is not required.
Leuze electronic
BCL 8
9600
8N1
no
framing protocol without acknowledgment
<STX> <Data> <CR> <LF>
Meaning
Version query
Activation / deactivation reading gate
Reference-code 1 teach-in
Reference-code 2 teach-in
Automatic configuration of reading task activation / deactivation
Switching output 1 activation
Switching output 1 deactivation
System standby
System active
Query reflector polling
Output version of the boot kernel with check sum
Output version of the decoder program with check sum
Reset parameters to default values
Device restart
Specifications for Leuze end devices
MA
208i
Corresponds to
serial command
(ASCII)
v
+ / -
RT1
RT2
CA+ / CA-
OA1
OD1
SOS
SON
AR?
VB
VK
PC20
H
69

Advertisement

Table of Contents
loading

Table of Contents