  • Page 1 Integra CUSA Clarity ® ® Ultrasonic Surgical Aspirator System Cleaning Instruction Guide...
  • Page 2 Integra CUSA ® Clarity – Ultrasonic Surgical Aspirator System ® Disassembling, Cleaning, and Sterilizing the System Disassembling the System PREFACE CUSA Clarity Items to Keep and Discard After a Surgical Procedure ® Intended Audience Keep Discard Handpiece Nosecone This cleaning instruction guide and the equipment it describes are for use only by qualified medical professionals trained in the par- ticular technique and surgical procedure to be performed.
  • Page 3 Integra CUSA ® Clarity – Ultrasonic Surgical Aspirator System ® Disassembling, Cleaning, and Sterilizing the System Disassembling the Console 5. Slide the flue off of the nosecone base along the tip. 6. Twist off the nosecone counter-clockwise until it unlocks.
  • Page 4 The CUSA Clarity cleaning brush is provided non-sterile and is not intended for use in a sterile environment. It is intended to be used Cleaning the System and stored only in the reprocessing unit of the healthcare facility.
  • Page 5 Most Common Sterilization Tray Configuration Packaging the Handpiece and Components for Sterilization The handpiece and components need to be packaged for sterilization. Integra provides a 23 kHz and 36 kHz sterilization tray for each of its corresponding handpieces The provided trays are intended to protect the CUSA Clarity Handpiece, EUT, and Torque Base during steam sterilization and during transfer to the sterile field.
  • Page 6 The CUSA Clarity handpiece and components must be sterilized with steam. The CUSA Clarity handpieces and components can be effectively sterilized with alternate cycles between the ranges of the validated sterilization cycles outlined in the tables above. If an alternative sterilization cycle is used, it is recommended that the reprocessor Sterilization Tray Packaging ensures use of FDA cleared sterilizers and accessories for the alternative sterilization cycle.
  • Page 7 Ireland Integra, the Integra logo, and CUSA are registered trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States and/or other countries. CUSA Quick Connect is a trademark of Integra LifeSciences Corporation or its subsidiaries. Sani-Cloth is a registered trademark of Professional Disposables International, Inc. neodisher is a trademark of Chemische Fabrik Dr.