Installation - Delfield N8000 Service, Installation And Care Manual

Drop ins, hot food wells, cold pans, granite cold slabs, frost tops and hot/cold food wells
Table of Contents

Advertisement

N8000 Series Drop-In Installation and Operation Manual

Installation

N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200, N8200G, N8100-FA & 8100-EF
These units are intended for indoor use only.
temperature of no more than 86°F (30°C) is recommended.
Be sure the location chosen has a counter strong enough to
support the total weight of the unit and contents. A fully loaded
model may weigh as much as 600 pounds! Reinforce the
counter as necessary to provide maximum loading.
Unit requires that the sides and bottom are not
any closer than 3" (7.6cm) to any combustible
material.
D A N G E R
The counter cut-out sizes and power requirements are shown
on the specification pages. A gasket is installed in the flange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
Louvers
Self-contained refrigerated units (N8100, N8100NB, N8100-BR,
N8200 and N8200G Series) require airflow to the compressor.
A 13" x 25" (33 cm x 63.5 cm) louver is provided by Delfield and
must be installed in the counter in front of the condenser. The
louver cutout dimension is 11" x 22" (27.9 cm x 55.9 cm). The
rear must have an opening to permit removal of heated air. The
opening must be at least 8" x 11", a total of 88 square inches
(20.3 cm x 27.9 cm, a total of 566 square centimeters).
Plumbing
The units drain must have an outlet to an appropriate drainage
area or container. A drain trap must be installed. N8200 series
have 1/2" drain and N8200G series have 3/4" drain located on
end/center. The 1" diameter drain on N8000, N8000-R, N8100,
N8100NB, N8100-BR, N8100-FA and 8100-EF Series units
is shipped loose and must be connected during installation.
N8157-FA, N8169-FA, and N8182-FA have two drains.
Installation N8600
These units are intended for indoor use only. A room temperature
of no more than 86°F (30°C) is recommended. Be sure the
location chosen has a counter strong enough to support the
total weight of the unit and contents. A fully loaded model
may weigh as much as 600 pounds! Reinforce the counter as
necessary to provide for maximum loading.
Unit requires that the sides and bottom are not
any closer than 3" (7.6cm) to any combustible
material.
D A N G E R
The counter cut-out sizes and power requirements are shown
on the specification pages. A gasket is installed in the flange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
The cut-out dimensions for the control box on N8600 Series
units is 4.25" x 12.25" (10.8 cm x 31.1 cm).
Louvers
For proper refrigerated operation, N8600 Series units require
airflow to the compressor. A 13" x 25" louver is (33.0 cm x 63.5
cm) is provided by Delfield and must be installed in the counter
in front of the condenser. The louver cutout dimension is 11"
10
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Moisture collecting from improper drainage
A room
can create a slippery surface on the floor
and a hazard to employees. It is the owner's
responsibility to provide a container or outlet
CAUTION
for drainage.
Some N8000, N8000N, N8000-R, N8100B,
N8100NB
polyethylene insulation in the drain hole.
This can easily be cut out without any contact
or damage to the units interior insulation or
refrigeration lines.
Electrical connection
Refer to the amperage data on the specification pages, the
serial tag or your local code to be sure the unit is connected
to the proper power source. A protected circuit of the correct
voltage and amperage must be run for con nec tion of the line
cord.
Some units have an ON/OFF switch located behind the
louvered panel in the machine compartment. Simply turn the
switch to ON to begin operation.
Some units have an OFF position on the thermostat dial which is
located behind the louvered panel in the machine compartment.
Simply turn the dial to begin operation.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
x 22" (27.9 cm x 55.9 cm). The rear must have an opening to
permit removal of heated air. The opening must be at least 8" x
11" , a total of 88 square inches (20.3 cm x 27.9 cm, a total of 566
square centimeters).
Plumbing
The units 1" (2.54cm) drain must have an outlet to an appropriate
drainage area or container.
Moisture collecting from improper drainage
can create a slippery surface on the floor
and a hazard to employees. It is the owner's
responsibility to provide a container or outlet
CAUTION
for drainage.
Electrical connection
Refer to the amperage data on the specification pages, the
serial tag or your local code to be sure the unit is connected to
the proper power source.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
and
N8100-BR
may
Delfield
have
®

Advertisement

Table of Contents
loading

Table of Contents