7.1 Modbus addresses for important device and process data
All process values (variables) together with their addresses, data types and
access modes are described below.
References are as follows:
R
read access only
W
write access only
R/W
read and write access
char
ASCII character (8 bits)
byte
byte (8 bits)
int
integer (16 bits)
char xx
character string of length xx;
xx = length, including the string termination character "0"
bit x
bit No. x
float
float value (4 bytes)
double
double value (8 bytes)
bool
boolean variable
The process values are divided into logical groups.
In the following address tables, bit 0 is always the least significant bit.
Address
Access
0x0009
R
0x1000
R
0x1017
R/W
0x120F
R
0x1211
R
0x1213
R
0x1215
R
0x1217
R
0x1219
R
0x121B
R
0x1221
R
0x1227
R
0x122D
R
Data type Signal designation
char 12
software version
char 46
device name
byte
display brightness
long
hardware count 1
long
hardware count 2
long
hardware count 3
long
hardware count 4
long
hardware count 5
long
hardware count 6
char 11
software version, card 1
char 11
software version, card 2
char 11
software version, card 3
char 11
software version, Profibus
7 Address tables
43