TEST LIMITS: Enables or disables the test limit(s). Toggle the Test Limits soft key between
On and Off.
HIGH LIMIT: Sets the upper limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
LOW LIMIT: Sets the lower limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
PHASE ERROR PEAK: Sets the peak of the phase error (in degrees) between the measured
phase and the ideal phase of a TCH timeslot, at a single instant. The GSM standard specifies the
peak phase error not to exceed 20 degrees during the useful part of the GSM burst.
TEST LIMITS: Enables or disables the test limit(s). Toggle the Test Limits soft key between
On and Off.
HIGH LIMIT: Sets the upper limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
LOW LIMIT: Sets the lower limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
EVM RMS: Sets the RMS of the error vector magnitude, which is measured and calculated over
the useful part of the burst, and is shown as a percentage.
TEST LIMITS: Enables or disables the test limit(s). Toggle the Test Limits soft key between
On and Off.
HIGH LIMIT: Sets the upper limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
EVM PEAK: Sets the peak of the error vector magnitude, which is measured and calculated over
the useful part of the burst, and is shown as a percentage.
TEST LIMITS: Enables or disables the test limit(s). Toggle the Test Limits soft key between
On and Off.
HIGH LIMIT: Sets the upper limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
IQ ORIGIN OFFSET: Sets I/Q origin offset value in dB of the I and Q error (magnitude squared)
offset from the origin.
TEST LIMITS: Enables or disables the test limit(s). Toggle the Test Limits soft key between
On and Off.
HIGH LIMIT: Sets the upper limit. Use the numeric keys to input value and press the unit soft
key or the ENTER hard key to complete the input.
C/I: Sets the Carrier to Interference (C/I) ratio in dB.
TEST LIMITS: Enables or disables the test limit(s). Toggle the Test Limits soft key between