Instructions for the installer

3.13 ELECTRICAL CONNECTIONS

GENERAL RECOMMENDATIONS
Electrical safety of the appliance is only ensured when it is correctly connected
to an efficient earthing system as specified by current safety standards: gas,
water and heating system pipes are not suitable in any way whatsoever as
earthing connections.
It is necessary to check this fundamental safety requirement; In case of doubt,
have an accurate inspection of the electrical system carried out by profession-
ally qualified personnel, as the manufacturer is not responsible for any damage
caused by the lack of a earthing connection in the system.
Have professionally qualified personnel make sure the electrical system is suit-
44
F1
54
TL
55
51
E
BK
BK
KEY
33
D
38
43
44
50
FL
FL
38
Wiring
Description
diagram
Heat adjuster HSCP
BMM
Burner management board
BCM
230 V power supply clamps
F1
Boiler pump
Fuse power supply 6.3 A
able for the maximum power absorbed by the appliance, as stated on the plate,
making sure in particular that the section of the system's cables is suitable for
the power absorbed by the appliance.
For the main power supply to the appliance, never use adapters, multiple sockets
and/or extension leads.
The use of components involving use of electrical power requires some
fundamental rules to be observed such as:
- do not touch the appliance with wet and/or moist parts of the body and/or
barefoot;
- do not pull the electric cables;
- the appliance may not be used by children or unskilled individuals.
A3
A4
A5
A1
A2
Y3
Y2
Y1
1 2 3 4 5 6 7
1 2 3
1 2
50
33
00330914
ATTENZIONE!
ATTENTION!
ACHTUNG!
ATENCIÓN!
ATTENTIE!
UPOZORNÌNÍ!
38
230 V
General manual reset limit thermostat
51
TLG
(model 350)
54
LTGL
Limit thermostat lamp TLG (model 350)
55
Main boiler switch
E
Power supply distribution board
Connection for flow switch
FL
Wieland power plug 230V - 50Hz
D
26
4
3
2
1
3
2
1
12 11 10 9 8 7 6 5 4 3 2 1
Y3
Jp2
Y4
Y2
1
2
3
4
5
6
7
8
9
10 11 12 13 14
1 2 3 4 5 6
43
00330914
ATTENZIONE!
ATTENTION!
ACHTUNG!
ATENCIÓN!
ATTENTIE!
UPOZORNÌNÍ!
230 V
38