ELECTRICAL CONNECTION.

The kit has an IP20 protection rating; electrical
safety of the appliance is achieved only when it
is properly connected to an efficient earthing
system, as specified by current safety standards.
Attention: the manufacturer declines any re-
sponsibility for damage or physical injury caused
by failure to connect the kit to an efficient earth
system or failure to comply with IEC reference
standards.
Important: it is mandatory to prepare two elec-
trical connection lines in order to separate the
electrical power supply from all other low-voltage
connections, according to the standards in force
regarding electrical systems.
The electrical connection between the devices
must be made using cables with a minimum
section of 0.50 mm
and with a maximum section
2
of 2.5 mm
; the length of these connections must
2
not exceed 15 metres.
System with high temperature zones
LED
Off
DL1
No remote control communica-
(Red)
tion in OT-S1
DL2
Operation with TA2
(Red)
DL3
Operation with TA3
(Red)
DL4
Operation with TA4
(Red)
DL5
No communication with boiler
(Green)
System with 1 high temperature zone and 1 low temperature zone.
LED
Off
DL1
No remote control communica-
(Red)
tion in OT-S1
DL2
Operation with Room Ther-
(Red)
mostat
DL3
Mixing valve stopped
(Red)
DL4
Mixing valve stopped
(Red)
DL5
No communication with boiler
(Green)
Error
Anomaly signalled
Code
IMG Bus communica-
36
tion loss
Communication
failure between remote
68
control and multi-zone
kit
System protection
46
thermostat fault
Low temperature zone
55
probe anomaly
(1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical After-Sales Service).
Perform the electrical connection as required and
as shown in the following wiring diagrams (Par.
"Wiring diagrams").

SYSTEM USE.

- DHW temperature setting. The domestic hot
water temperature is controlled by the "master"
remote control, i.e. the one connected to the
OT-S1 channel of the kit connected to the boil-
er. The settings made on the remaining remote
controls for domestic hot water are ignored.
- Flow temperature setting. The boiler flow
temperature for central heating can be ad-
justed on each remote control as required. Or
in the case of a system controlled from room
thermostats, the flow temperature is set on the
relative parameters (Par. "Programming the
P.C.B. " ). The system takes into consideration
the highest temperature in order to meet all
the active requests.
On
Remote control 1 presence
Remote control 2 presence
Remote control 3 presence
Remote control 4 presence
Communication with boiler in
progress
On
Remote control presence in
OT-S1
Remote control presence in
OT-S2
Mixing valve opening
Mixing valve closing
Communication with boiler in
progress
Cause
Communication between the components is inter-
rupted due to a fault on the boiler, multi-zone kit
or IMG Bus.
Due to a fault, communication between remote
control and multi-zone kit is interrupted.
The board detects a fault on the system protection
thermostat (optional).
The board detects a fault on the low temperature
probe (optional).
The system operating status is indicated by LEDs
(Ref. 10 Fig. 12 ) according to the relative tables
(Fig. 13).

FAULT AND ANOMALY SIGNALS.

The P.C.B. reports a fault by means of a code
shown on the remote control display, according
to the table below and the table in the boiler
instruction booklet. Depending on the settings
of the relevant parameters, it is possible to decide
on which remote control the fault is displayed
(Par. "Programming the P.C.B. " ).
Slow Flashing
Zone 1 active request
Zone 2 active request
Zone 3 active request
Zone 4 active request
Boiler in domestic hot water
operating mode
Slow Flashing
Zone 1 active request
Zone 2 active request
/
/
DHW request in progress
Disconnect and reconnect the power to the boiler. If the
Remote Control is still not detected on re-starting, the
boiler will switch to local operating mode, i.e. using the
controls on the control panel. In this case, the boiler
will not meet the heating requests (1)
Check the connection between the devices. In this case,
the boiler will meet the heating requests according to
the settings of the "Emergency Function" parameters
(1)
The requests of the mixed zone (low temperature) are
not met (1)
The requests of the mixed zone (low temperature) are
not met (1)
14
Fast Flashing
Open safety thermostat
/
Low temperature zone probe
anomaly
(simultaneous flashing)
/