System Status Led; Ethernet Management Port Link Status And Activity Leds - Brocade Communications Systems 7810 Hardware Installation Manual

Extension switch
Table of Contents

Advertisement

Interpreting Port-Side LEDs
TABLE 9 System Power LED Patterns During Normal Operation (continued)
LED Color
Steady green

System Status LED

See the following table to interpret the system status LED.
TABLE 10 System Status LED patterns During Normal Operation
LED Color
No light
Steady green
Steady amber (for more than 5 seconds—can
take over a minute to complete the POST)
Steady amber (for more than a few minutes)
Flashing amber/green

Ethernet Management Port Link Status and Activity LEDs

See the following table to interpret the Ethernet management port status and activity LEDs.
The status LED is the leftmost LED under the port.
The activity LED is the rightmost LED under the port.
TABLE 11 Management Port Link Status LED Patterns During Normal Operation
LED
No light (LED is off)
Green (LED is on)
60
Status of Hardware
The system is on and power supplies are
functioning properly.
Status of Hardware
The system is off or there is no power.
The POST and initialization have completed. The
system is on and functioning properly.
System is going through the power-up process.
Unknown state, boot failed, or the system is
faulty.
NOTE
Once the POST completes and the
switch has failed, a steady amber
color may result.
Attention is required. A number of variables can
cause this status, including a single power
supply failure, a fan failure, or one or more
environmental ranges being exceeded.
Status of Hardware
The Ethernet link speed is 10/100Mb/s or the
link is not established.
The Ethernet link speed is 1000Mb/s.
The Ethernet link is healthy and traffic is flowing
through the port.
Recommended Action
If the system power LED is not green, the unit
may be faulty.
Contact your solution provider.
No action is required.
Recommended Action
Verify that the system is on and has completed
booting.
No action is required.
No action is required.
Perform the following steps:
1.
Connect a serial cable to the system.
2.
Reboot the system.
3.
Check the failure indicated on the
system console
4.
Contact your solution provider.
Check the management interface and the error
log for details on the cause of the status.
Contact your solution provider.
Recommended Action
Ensure that the switch has power.
No action is required.
Brocade 7810 Extension Switch Hardware Installation Guide
7810-IG101

Advertisement

Table of Contents
loading

Table of Contents