5.2.2

Wiring diagram: Outdoor unit

See the internal wiring diagram supplied with the unit (on the inside of the top plate). The abbreviations used are listed below.
Class 20~35
(1) Wiring diagram
English
Wiring diagram
Wiring diagram
Indoor
Indoor
Outdoor
Outdoor
Condenser
Condenser
Discharge
Discharge
(2) Notes
English
Connection
X1M
Main terminal
Field supply
PCB
Protective earth
Earth
Field wire
NOTES:
BLK : Black
WHT : White
BRN : Brown
RED : Red
GRN : Green
YLW : Yellow
ORG : Orange
BLU : Blue
GRY : Grey
For the power requirements, refer to the nameplate.
(C)(F)TXA15~50A2V1B(W)(S)(T) + RXA42+50A2V1B +
RXA20~35A2V1B
Split Stylish R32
ESIE18-03 – 2018.09
(3) Legend
C*
DB1
Translation
E1, E2, HL1, HN1, S
FU1, FU2, FU3
IPM*
L
M1C
M1F
MR*
Translation
N
PAM
PCB
PS
Q1L
R1T, R2T, R3T
S2 -S90
SA1
V2, V3, V150
X11A
X1M
Y1E
Y1S
Z*C
Z*F
5 Technical data
Capacitor
Diode bridge
Connector
Fuse
Intelligent power module
Live
Compressor motor
Fan motor
Magnetic relay
Neutral
Pulse‑amplitude modulation
Printed circuit board
Switching power supply
Overload protector
Thermistor
Terminal connector
Surge arrestor
Varistor
Connector
Terminal strip
Electronic expansion valve
Reversing solenoid valve coil
Ferrite core
Noise filter
Service manual