Wiring Diagram: Outdoor Unit - Daikin Sky Air Active Series Installation Manual

Hide thumbs Also See for Sky Air Active Series:
Table of Contents

Advertisement

11.3

Wiring diagram: Outdoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.
(1) Connection diagram
English
Connection diagram
Only for ***
See note ***
Outdoor
Indoor
Upper
Lower
Fan
ON
OFF
(2) Layout
English
Layout
Front
Back
Position of compressor terminal
(3) Notes
English
Notes
X1M
1
NOTES:
1
Refer to the wiring diagram sticker (on the back of the front
plate) for how to use the BS1~BS3 and DS1 switches.
2
When operating, do not short-circuit protective devices S1PH
S1PLand Q1E.
3
Refer to the combination table and the option manual for how
to connect the wiring to X6A, X28A and X77A.
4
Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN:
green, YLW: yellow.
(4) Legend
English
Legend
Field supply
Optional
Part n°
Description
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
AZAS100~140MUV/Y
Sky Air Active-series
4P743507-1 – 2023.08
Translation
Connection diagram
Only for ***
See note ***
Outdoor
Indoor
Upper
Lower
Fan
ON
OFF
Translation
Layout
Front
Back
Position of compressor terminal
Translation
Notes
Connection
Indoor/outdoor communication
Earth wiring
Field supply
Several wiring possibilities
Protective earth
Field wire
Wiring depending on model
Option
Switch box
PCB
Translation
Legend
Field supply
Optional
Part n°
Description
BS1~BS3 (A1P)
Push button switch on PCB
C* (A1P) (Y only)
Capacitor
DS1 (A1P)
Dipswitch
E* (A1P)
Terminal (noiseless earth)
F*U
Fuse
H*P (A1P)
Light-emitting diode (service monitor is
green)
K1M, K3M (A1P) (Y
Magnetic contactor
only)
K1R (A1P)
Magnetic relay (Y1S)
K2R (A1P)
Magnetic relay (Y2S)
K10R, K13R~K15R
Magnetic relay
(A1P)
K11M (A1P) (V only)
Magnetic contactor
L* (A1P)
Terminal (live)
L1R (Y only)
Reactor
M1C
Compressor motor
M1F
Fan motor
N* (A1P)
Terminal (neutral)
PFC (A1P) (V only)
Power factor correction
PS (A1P)
Switching power supply
Q1
Overload protection
Q1DI
Earth leakage circuit breaker (30 mA)
R1~R8 (A1P) (Y only)
Resistor
R1T
Thermistor (air)
R2T
Thermistor (discharge)
R3T
Thermistor (suction)
R4T
Thermistor (heat exchanger)
R5T
Thermistor (heat exchanger middle)
R6T
Thermistor (liquid)
R7T
Thermistor (fin)
R8T~R10T (A1P )
Thermistor (PTC)
R11T (A1P ) (Y only)
Thermistor (PTC)
R501~R962 (A1P )
Resistor
(V only)
R2~R981 (A1P ) (Y
Resistor
only)
R*V (A2P ) (V only)
Varistor
S1PH
High pressure switch
S1PL
Low pressure switch
SEG* (A1P)
7-segment display
TC1 (A1P)
Signal transmission circuit
V1D (A1P) (V only)
Diode
V1D~V2D (A1P) (Y
Diode
only)
V*R (A1P)
Diode module/ IGBT power module
X*A
Connector
X1M
Terminal strip
Y1E, Y3E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)
Y2S
Solenoid valve (gas receiver)
Z*C
Noise filter (ferrite core)
Z*F
Noise filter