Swing Raster Motor; Checking Procedures - Daikin Stylish Series Service Manual

Split stylish r32
Hide thumbs Also See for Stylish Series:
Table of Contents

Advertisement

2 Components
4 Remove the 3 screws from the swing flap motor gear case
assembly. Do NOT yet remove the assembly from the indoor
unit.
a
b
a
a
Screw
b
Swing flap motor gearcase assembly
5 Disconnect the rocker arm from the swing raster.
6 Remove the swing flap motor gear case assembly from the
indoor unit.
7 Disconnect the harness from the swing flap motor.
8 Disconnect the harness from the swing raster motor.
9 To install the swing flap motor gearcase assembly, see
procedures" on
page 47.
To install the swing flap motor gearcase assembly
1 Connect the harness to the swing raster motor connector.
2 Install the swing flap motor gearcase assembly on the indoor
unit. Install the 3 screws, but do NOT yet tighten them.
a
b
a
a
Screw
b
Swing flap motor gearcase assembly
3 Connect the rocker arm to the swing raster.
Service manual
48
b
a
c
a
Fan guard
b
Rocker arm
c
Swing raster
4 Tighten the 3 screws to fix the swing flap motor assembly.
5 Connect the harness to the swing flap motor connector.
6 Install the right side fan guard on the indoor unit (by clicking it
on).
7 Install the secondary swing flap in the indoor unit (by clicking it
on).
"Repair
8 Install the main swing flap in the indoor unit (by clicking it on).
Is the problem solved?
Yes
No
2.17

Swing raster motor

a
2.17.1

Checking procedures

To perform an electrical check of the swing raster
motor
Prerequisite: Turn OFF the unit via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
work" on
page 40.
1 Disconnect the motor connector from the indoor unit PCB.
2 Measure the resistance between the following pins of the motor
connector. The measurements MUST be as shown in the table
below.
Pins
1-2
1-3
1-4
1-5
2-3
2-4
2-5
3-4
3-5
4-5
(C)(F)TXA15~50A2V1B(W)(S)(T) + RXA42+50A2V1B +
a
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
"2.13  Plate
Measured resistance (Ω)
235
470
RXA20~35A2V1B
Split Stylish R32
ESIE18-03 – 2018.09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents