Do not attempt to resolve any faults without first having read and understood the machine's
operating instructions and safety regulations.
PROBLEM
The motor will not start
The motor suddenly shuts
off
072010

Troubleshooting Guide

POSSIBLE CAUSE
Dead battery
EMERGENCY stop button
pressed
Emergency stop cable pressed
No fuel
Plug not inserted or incorrectly
connected to the control unit that
manages the safety devices
Breakdown of the safety device
control unit
Breakdown of the motor of the
hydraulic power unit.
Excessive motor temperature
Air pressure from the compressor
is too low or the compressor is off
No fuel
58
REMEDY
Replace
the
battery
hydraulic power unit.
Release the emergency stop button
and
reset
the
safety
interlock (pages 18-19).
Release the emergency stop cable
and
reset
the
safety
interlock (pag. 18).
Fill the tank with fuel and restart
the motor on the power unit (pages
29-30-25).
Correctly connect the plugs of the
control unit that manages the
safety devices (page 25)
Contact the Marini Quarries Group
(*) customer service department
Contact the Marini Quarries Group
(*) customer service department
Allow the motor to cool before
restarting the work.
Restore the air pressure, reset the
safety device interlock and restart
the motor on the power unit (page
33).
Fill the tank with fuel and restart
the motor on the power unit (pages
29-30).