Table 13 - 1-Phase, 2-Input, 2-Multiplication Operation Mode; Figure 5 - Up/Down Count Operation By B-Phase Input Signal - Honeywell 2MLF-HO2A User Manual

High speed counter module
Table of Contents

Advertisement

Table 13 – 1-Phase, 2-Input, 2-Multiplication Operation Mode
Up/Down count
classification
B-phase input pulse OFF
B-phase input pulse ON
Figure 5 – Up/Down Count Operation by B-Phase Input Signal
2.
2-Phase Input Mode
a)
2-phase, 1-multiplication operation mode: The counter counts A-phase
pulse input at the rising edge.
If A-phase input pulse precedes B-phase input pulse, up count operation starts at
the rising edge of A-phase pulse input.
If B-phase input pulse precedes A-phase input pulse, down count operation starts
at the falling edge of A-phase pulse input.
Up/Down count
classification
A-phase input pulse
precedes B
B-phase input pulse
precedes A
R200
2MLF-HO2A, 2MLF-HD2A High Speed Counter Module User's Guide
May 2010
A-Phase input pulse rising
Up count
Down count
A-Phase input pulse rising
Up count
-
Honeywell
2. Specifications
2.4. Counter Functions
A-Phase input pulse falling
Up count
Down count
A-Phase input pulse falling
-
Down count
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2mlf-hd2a

Table of Contents