AUDIO ALARM VERIFICATION MODULE
The INT-AV module enables audio alarm verification to reduce the number of false alarms.
After having received alarm message from the control panel, the operator of telephone
monitoring station is able to listen-in on the sounds coming from the premises to confirm
whether there is an intrusion. Owing to the module, the operator can try to contact the people
on the premises to determine if the alarm is real or false. The listen-in and talk features are
also available to the alarm system users. They can call the control panel number and, after
entering the telephone code, get access to these features at any time.
Listen-in and communication with the people on the protected premises are possible due to
the INT-AVT terminals. The terminal is equipped with a microphone and a speaker. The
module delivery set includes one INT-AVT terminal. Up to four INT-AVT terminals can be
connected to the module.
The module works with the INTEGRA / INTEGRA Plus control panels (firmware version 1.12
or newer). This manual applies to the module electronics version 1.4 and firmware version
1.00 (or newer).
Notes:
 Only one INT-AV module can be connected to the control panel.
 If an INT-VG module is connected to the control panel, the module firmware version must
be 1.02 or newer.
1. INT-AV module features
 Two-way (listen-in / talk) audio alarm verification.
 Keeping telephone connection with the monitoring station open after the control panel has
sent alarm message (line hold mode).
 Receiving phone calls from the monitoring station after the control panel has sent alarm
information (call back mode).
 Availability of the listen-in / talk features to the users having a telephone code.
 Support for up to four INT-AVT terminals.
2. Specifications
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ..........................................................................................35 mA
Maximum current consumption (INT-AV + 1xINT-AVT) .................................................160 mA
Maximum current consumption (INT-AV + 4xINT-AVT) .................................................500 mA
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range..................................................................................-10...+55 °C
Maximum humidity .......................................................................................................... 93±3%
Dimensions
INT-AV (electronics board) ............................................................ 57 x 80 mm
INT-AVT (enclosure).............................................................35 x 127 x 22 mm
int-av_en 08/13

Advertisement

loading
Need help?

Need help?

Do you have a question about the INT-AV and is the answer not in the manual?

Questions and answers

Summary of Contents for Satel INT-AV

  • Page 1 AUDIO ALARM VERIFICATION MODULE int-av_en 08/13 The INT-AV module enables audio alarm verification to reduce the number of false alarms. After having received alarm message from the control panel, the operator of telephone monitoring station is able to listen-in on the sounds coming from the premises to confirm whether there is an intrusion.
  • Page 2: Electronics Board

    INT-AV SATEL Weight INT-AV....................... 46 g INT-AVT..................... 42 g The declaration of conformity may be consulted at www.satel.eu/ce 3. Electronics board Fig. 1. Module electronics board. DIP-switch package (see DIP- SWITCHES wires to the PIN5 type plug used for connecting the module to a dedicated socket on the control panel electronics board (socket to connect a voice synthesizer).
  • Page 3: Installation

    The permissible distance between the communication terminal and the module is 100 m. Note: Resistance of the wires connecting the INT-AVT unit with the INT-AV module has an effect on the audio playback volume (the higher the resistance, the lower the volume) and the current consumption.
  • Page 4 INT-AV SATEL Fig. 2. The way of connecting INT-AVT units to INT-AV module. Proceed in the same way to connect next units (i.e. unit 3 to screw terminals designated with digit 3, and unit 4 to screw terminals designated with digit 4).
  • Page 5: Lcd Keypad: S

    LOAD "Exp. modules identification" button. The control panel controls presence of the identified modules, and in the case of the INT-AV module, also for presence of the INT-AVT terminals connected to the module. Disconnecting the module from communication bus, changing the position of DIP-switches, swapping the module with another one, in which the DIP-switches are set in the same way, or disconnecting the INT-AVT terminal, will trigger the tamper alarm.
  • Page 6 Name – individual device name (up 16 characters). Station access phone code [INT-AV code] – the code the monitoring station operator must enter to be able to initiate the listen-in / talk session. Verif. after reporting [Verify] – you can specify for each telephone number of the monitoring station whether, in the event of an alarm, message on the possibility to initiate the listen-in / talk session is to be sent.
  • Page 7 Listen-in only in silent alarm [Silent alarm] – if this option is enabled, only the listen-in feature will be available in the event of silent alarm. SATEL standard commands – if this option is enabled, the module can be operated by means of DTMF commands compliant with SATEL standard, and if it is disabled, by means of DTMF commands compliant with SIA standard.
  • Page 8 INT-AV SATEL Line hold mode Having sent information on the possibility of using the listen-in / talk features, the control panel will hold the phone line open for 15 seconds. If, during this time, the control panel receives any DTMF tone, the call holding time will be prolonged. It will allow the operator to enter the code to initiate the listen-in / talk session (the module can be configured so as to start a listen-in / talk session by pressing any key on the phone, i.e.
  • Page 9 SATEL INT-AV 7.3 DTMF commands After starting the listen-in / talk session, the level 0 commands are available. Level 0 Standard SATEL Command description Returns to the initial session settings Activates high gain talk to the premises from all speakers...
  • Page 10: Updating Module Firmware

    8. Updating module firmware When a new version of the module firmware comes out, it will be available on the www.satel.eu site. Run the program downloaded from the manufacturer's site. Instructions will be displayed regarding the firmware update procedure. Note: When updating the module firmware, make sure that the DIP-switches 3 and 4 on the...
  • Page 11 SATEL sp. z o.o. • ul. Schuberta 79 • 80-172 Gdańsk • POLAND tel. 58 320 94 00 • info@satel.pl www.satel.eu...