  • Page 1 Advantix Cleviva shower channel base unit (reconstruction model) Instructions for Use for bonded sealing (tiled shower). Model Year built: 4981.81 from 03/2019 en_INT...
  • Page 2 Advantix Cleviva shower channel base unit (reconstruction model) 2 from 30...
  • Page 3: Table Of Contents

    Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Standards and regulations Intended use 2.2.1 Areas of use 2.2.2 Media 2.2.3 Drainage capacity Product description 2.3.1 Installation variations 2.3.2 Overview of the components 2.3.3...
  • Page 4: About These Instructions For Use

    This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
  • Page 5: About This Translated Version

    About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g.
  • Page 6: Product Information

    Product information 2 Product information Standards and regulations The following standards and regulations apply to Germany / Europe and are provided as a support feature. Regulations from section: Sealing Scope / Notice Regulations applicable in Ger‐ many Stress class of the underground, ZDB-Merkblatt 8/2012 as well as suitable bonded sealing Stress class of the underground,...
  • Page 7: Intended Use

    Product information Regulations from section: Important notes Scope / Notice Regulations applicable in Ger‐ many Dimensions of slots and recesses EN 1996 Intended use 2.2.1 Areas of use The shower channel is used in the bathroom as a drain for a floor-level shower.
  • Page 8: Product Description

    Product information Product description 2.3.1 Installation variations The length of the Cleviva shower channel can be adjusted. The shower channel profile can be shortened to a length of 300 mm with millimetre precision. 2.3.2 Overview of the components Fig. 1: Components and scope of delivery height adjustment piece Site protection (composite wood) Sieve insert...
  • Page 9: Technical Data

    Product information 2.3.3 Technical data Nominal width [DN] 40 / 50 Material Plastic odour trap Shower channel profile from stainless steel 1.4301 Drainage capacity Ä Chapter 2.2.3 „Drainage capacity“ on page 7 Dimensions and installa‐ Ä Chapter 3.1.3 „Installation dimen‐ tion height sions“...
  • Page 10 Product information Important note Careful planning is required for professional sealing. In addition, depending on the individual dampness wear class and the type of foun‐ dation, a suitable thin bed bonded sealing with a building regulations certificate of suitability must be chosen. Furthermore, the following factors should be taken into account: The drain or shower channel must be equipped with a special flange, which has an adhesive surface and a width of at least 50 mm.
  • Page 11: Required Accessories

    Product information Required accessories For the complete assembly of the shower channel base unit a shower channel insert (model 4981.50 or 4981.60) and a shower channel profile (model 4981.30, 4981.31 or 4981.32) are also required. Advantix Cleviva shower channel base unit (reconstruction model) 11 from 30...
  • Page 12: Handling

    Handling 3 Handling Assembly information 3.1.1 Important note Before assembly: Check if the drainage capacity of the model chosen is sufficient for the arising water volume Ä Chapter 2.2.3 „Drainage capacity“ on page 7. In the case of the connection of two or three shower channels: Observe the information for dimensioning of collective lines Ä...
  • Page 13: Installation Dimensions

    Handling 3.1.3 Installation dimensions Shower channel, basic model with one base unit Fig. 3: Dimensions of base unit basic model Advantix Cleviva shower channel base unit (reconstruction model) 13 from 30...
  • Page 14: Assembly

    Handling Assembly 3.2.1 Determine height The tiler set has to be handed over to the person respon‐ sible for the bonded sealing (tiler). Determine the screed height H. The installation height is 70–155 mm. Shorten the dimension X on the mounting flange. X = 155 mm - H Deburr the mounting flange.
  • Page 15: Fitting The Mounting Flange

    Handling 3.2.2 Fitting the mounting flange Insert the profile seal. Apply a coat of lubricant for plastic pipes to the inside of the profile seal. Push the flange into the odour trap as far as it will go. Advantix Cleviva shower channel base unit (reconstruction model) 15 from 30...
  • Page 16 Handling The flange can be rotated around 360°. Turn the transition to eccentrically offset the drain by up to 8.5 mm. Advantix Cleviva shower channel base unit (reconstruction model) 16 from 30...
  • Page 17: Aligning And Connecting

    Handling 3.2.3 Aligning and connecting Position the odour trap. The arrows on the flange acts as alignment aids. INFO! Fit a sound insulation mat beneath the odour trap as an option. – 8 mm, art. no. 791 650 – 3 mm, art. no. 790 448 Shorten the connection pipe as required.
  • Page 18 Handling Secure the drain. INFO! Use fixing set article no. 497 003 as an option. Advantix Cleviva shower channel base unit (reconstruction model) 18 from 30...
  • Page 19 Fig. 4: Interval to wall, odour trap model 4981.11 / 4981.81 X = minimum interval to wall Y = maximum interval to wall Interval to wall, odour trap model 4981.11 / 4981.81 interval Minimum X 27 mm 16 mm...
  • Page 20 Handling check for leaks Lift up the label. Fill the drain unit with water. Check the drain casing and the connection line for leaks. Re-affix the label. Lining with screed Align the flange horizontally in all directions. NOTICE! Product damage due to improper installation If hollow spaces occur during the lining of the shower channel, leaks may occur when pressure is applied.
  • Page 21: Sealing The Shower Channel

    Handling 3.2.4 Sealing the shower channel – The seal set has to be handed over to the person respon‐ sible for the bonded sealing (tiler). – Only use the sealing accessories included in the scope of delivery. – For wall mounting, work the sealing collar on the upright wall into the bonded sealing.
  • Page 22 Handling INFO! Observe the bonded sealing manufacturer's instructions for use. Fold together the sealing collar. Apply the first layer of bonded sealing generously onto the screed and the flange. Push the sealing into the bonded sealing, which is still in the liquid state, without wrinkles.
  • Page 23: Mounting Height Adjustment Piece And Shower Channel Profile

    Handling 3.2.5 Mounting height adjustment piece and shower channel profile Determining dimensions The shower channel profile can be shortened. Coloured shower channel profiles must not be shortened. The shower channel profile is divided into two drain zones. Drain zone (flat, no incline) Drain zone (with contour, 1–2 % incline) The shower channel profile can be shortened by up to 100 mm at the ends of the drain zone.
  • Page 24 Handling Shortening range of drain zone for extended shower channel profiles Profile length Shortening range 2 x 800 mm 1200–1600 mm 2 x 1000 mm 1600–2000 mm 2 x 1200 mm 2000–2400 mm Shortening the shower channel profile Determine the required dimension and mark at right angles. Using a handsaw, shorten the shower channel profile at right angles and deburr.
  • Page 25 Determine the flooring height H. INFO! For fault-free drainage, Viega recommends laying the floor covering 1–2 mm higher than the shower channel profile. Due to the stepless shortening of the top, an installation height of at least A 12 mm to B 30 mm is possible for tiles and tile adhesive.
  • Page 26 Handling Lay the floor covering 1–2 mm higher than the shower channel pro‐ file. Dimension X = 30 mm - H Shorten dimension X along the cutting aid and deburr. Unroll the butyl tape and cut to size. Stick the butyl tape centrally on the underside of the shower channel profile.
  • Page 27 Handling Remove the protective foil. Apply the tile adhesive over the entire surface of the shower channel profile and the height adjustment piece. Remove the site protection. Do not damage the bonded sealing. Insert the shower channel profile and the height adjustment piece. Align the shower channel profile and the height adjustment piece horizontally.
  • Page 28 Handling To allow the shower channel profile to be adapted to the tile pattern, the profile mount is eccentrically positioned by 7.5 mm. After alignment, fasten the height adjustment piece with tile adhe‐ sive. Fit the insert. Two insert variants are available: Inlet opening double, model 4981.50 Inlet opening single, model 4981.60 Advantix Cleviva shower channel base unit (reconstruction model)
  • Page 29: Care

    There should be no residue on the components. 3.3.2 Cleaning Viega recommends using a mild cleaning agent, a cloth and a washing- up brush for cleaning. Clean shower channel Remove the grate element and the sieve.
  • Page 30: Disposal

    Handling Clean the odour trap. Replace the sieve and the grate element. Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements. Advantix Cleviva shower channel base unit (reconstruction model) 30 from 30...