Temperature Display

The temperature display reports the thermocouple temperature or an average of the multiple thermocouple
temperatures. The color of the main temperature display can be changed from Green to Red to Black by touching
the display area.
(Four dashes) appear on the controller display during power up. The 4 dashes are in place of the normal
thermocouple display temperature. This allows time for the initial temperature measurement to stabilize before it is
displayed.
For Multizone, the temperature display will show the average thermocouple of all the thermocouple inputs.

Temperature Units

If your controller is configured to display temperature values in °F, heating rates will be programmed as Degrees
Fahrenheit per hour and target temperatures will be programmed as Degrees Fahrenheit. If your controller is
configured to display temperature values in °C, heating rates will be programmed as Degrees Centigrade per hour
and target temperatures will be programmed as Degrees Centigrade. To change the temperature units, see the Units
screen.

Program Name

The name of the active firing program appears below the temperature display. User Program names can
have custom labels.

Status

the line below the Program name reports the status of the controller, this line will also provide access to alarm and
other information during an active kiln firing.
Status Messages
During an active firing, the info button (circled i) will bring up the Info Screen.

Start/Stop/Confirm

The button in the center of the screen is used to Start or Stop a firing. It is also used to clear and recognize alarm
messages when they appear. During an active firing, the START button becomes the STOP button.
AutoFire Slide Kiln Controller
STANDBY..................During idle operation
DELAY .....................During a delay period
RAMP #............................During a heating or cooling ramp
HOLD #........................... During a hold period
COMPLETE................Firing completed
ABORT.....................Alarm terminated the firing
STOPPED..................Operator Stopped the firing