Info Screen; Temperature; Setpoint; Rate/Hold - Orton AutoFire AF4TS User Manual

Slide kiln controller
Table of Contents

Advertisement

Info Screen

During an active firing. The info screen is available by touching the (Circle i) button that appears on the Status
line.

Setpoint:

Control Setpoint

Status:

Program status
Zone saturated:
Symbol for zone
control problem
Diagnostics:
Shows relay
activity and
thermocouple
temperatures
Skip:
Skip to the next
program ramp step

Temperature

Same as the Home screen. This is the main temperature display
Setpoint
Reports the controller setpoint to be compared with the actual temperature. The setpoint value should be close to
the actual temperature if the kiln is performing well.

Rate/Hold

Reports the actual heating rate during a ramp or the remaining hold time during a hold.
Status
Reports the program segment in progress.

Zone control Performance

If a triangle appears next to a heating zone, this represents a problem with the zone falling behind the program
AutoFire Slide Kiln Controller
Sound:
Silence the
audible alarm
21
Temperature:
Current
temperature
Rate/Hold:
Actual ramp rate
or remaining hold
time
Diagnostics:
Shows Output
power and amps
Add time:
Add 5 minutes to
the current
program ramp step

Advertisement

Table of Contents
loading

Table of Contents