About Screen

The About screen is accessed from the Configuration screen Slide button.

Version:

Reports the
Autofire software
version

Safety Temp:

Reports the
maximum
programmable
temperature
Version
Software version allows the operator to view the controller software version number.

Board Temp

Board Temperature allows the operator to view the measured board temperature. The on-board temperature is
measured at the thermocouple junction.
Note: The 'Electronics Hot' alarm will activate with a board temperature above 176ºF (80ºC)
Safety Temp
Safety Temperature allows the operator to view the maximum programmable temperature limit for the programs.
Changing the Safety temperature requires a passcode. Touch the Lock image in the middle of the screen, key in the
passcode 369 and SAVE to unlock the safety temp setting. When the screen returns to ABOUT, touch the setting
field for a pop-up keypad. Key in the new max temp for the kiln and SAVE.
The Safety temp will automatically lock again when you exit the screen.
AutoFire Slide Kiln Controller
27
Board Temp:
Reports the circuit
board temperature
Test:
Diagnostic test of
the inputs and
outputs
Reset:
Restore the
configuration
settings