AC POWER SCREENS LOAD SETTING SCREEN 1

The first Load Setting screen configures the
following settings:
Phase Detection

AC POWER SCREENS LOAD SETTING SCREEN 2

The second Load Setting screen configures the
following settings:
Manual / Automatic
Set to Manual for standard Transfer Switch.
Set to Automatic for RV-C Transfer Switch.
A RV-C Transfer Switch has the capability of
automatically detecting Dual Phase (240 VAC)
50 Amp AC power based on the available AC
power source.
Default Phase
Phase / Dual Phase
Selects the default Phase setting for the Load
Shedding function.
This setting sets the Load Shedding Amperage
value for the Single Phase selection.
Capacity Dual Phase (Amperage)
This setting sets the Load Shedding Amperage
value for the Dual Phase selection. This
should normally be set 50 Amps.
This setting sets the Load Shedding Amperage
value for the Dual Phase selection. This
should normally be set 50 Amps.
Load Shedding
Load Shedding Enabled allows the control
system to shed (turn off) system configured
AC powered devices in order to maintain a
maximum phase capacity AC amperage usage.
Generator Settling
This setting should be set to Enabled for
proper Auto Gen operation.
Charger 1 Shedding
This setting determines if the Battery Charger
should be shed (turned off) with the other
Load Shedding devices.
Single
Capacity - Single Phase
(Amperage)
Capacity - Dual Phase
(Amperage)
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled