NewMar PE Series Installation & Operation Manual

NewMar PE Series Installation & Operation Manual

Annunciator panel

Advertisement

Quick Links

Universal BBU Annunciator
Installation/Operation Manual
15272 Newsboy Circle
Huntington Beach
California 92649
PE Series
Annunciator Panel
Model: AP-8000
Section
Safety Information........................................... 1
General Information........................................ 1
Installation and Wiring................................... 1
Regulatory Information................................... 3
Troubleshooting..............................................
Limited Warranty............................................. 3
Circuit Board Illustration.................................. 4
Wiring Diagram............................................... 5
PoweringTheNetwork.com
Page
3
E-Mail: techservice@newmarpower.com
M-AP8000
As of 091119
Phone: 714-751-0488
Fax: 714-896-9679

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for NewMar PE Series

  • Page 1 PE Series Annunciator Panel Universal BBU Annunciator Installation/Operation Manual Model: AP-8000 Section Page Safety Information........... 1 General Information........1 Installation and Wiring........1 Specifi cations........... 3 Regulatory Information........3 Troubleshooting..........Limited Warranty..........3 Circuit Board Illustration........4 Wiring Diagram..........5...
  • Page 2: General Information

    Safety Information FOR COMMERCIAL USE ONLY CAUTION Up to 60 Volts DC may be present on the terminals. DO NOT SHORT ACROSS THE POWER SUPPLY TERMINALS • Keep fingers and all metal objects from power terminals and wires. • Use insulated hand tools. •...
  • Page 3 B) Wiring The following wiring is required to place the annunciator into service: 1) Connection to a power supply: See wiring diagram on page 5. Provide DC power from the DC output of the battery back-up (BBU) unit to the “Input Power” terminals located at the lower-left corner of the AP-8000 circuit board. This terminal accepts 12-22 AWG wire size.
  • Page 4: Specifications

    Warranty Newmar warrants that the AP-8000 PE Series Annunciator Panel to be free from defects in material and workmanship for two years from date of purchase. If a problem with your AP-8000 or if you have any questions about the installation and proper operation of the unit, please contact NEWMAR’s Technical Services Department:...
  • Page 5 Figure 2: Circuit Board Illustration DIP Switches, Alarm LEDs (8) POS 1: ON POS 2: OFF Power On POS 3: OFF Indicator POS 4: OFF EXPANSION LED 12 PORT Micro-processor POWER Heartbeat Indicator FAILURE LED 9 BATTERY RESET Reset Push-Button, CHARGER Contact Factory FAILURE...
  • Page 6 AC Fail OUTPUT: 48Vdc 10A techservice@newmarpower.com AC/L “+” Www.automationdcpower.com Relay 1 Relay 2 Relay 3 Newport Beach, CA USA NEWMAR Relay Repeater JUMPER FOR BATTERY 963-5983-0 Rev B 115 Vac AC Fail/On Batt Back-Up Low or Replace Battery Rectifier Fail ALARM...