And 16-** Profibus Parameters - Danfoss VLT PROFIBUS DP MCA 101 Programming Manual

Hide thumbs Also See for VLT PROFIBUS DP MCA 101:
Table of Contents

Advertisement

Parameters
8-52 DC Brake Select
Option:
Function:
[3] Logic OR
Activates start command via the fieldbus/serial
communication port OR via one of the digital
inputs.
8-53 Start Select
Option:
Function:
Select control of the frequency converter start
function via the terminals (digital input) and/or
via the fieldbus.
[0]
Digital
Activates a start command via a digital input.
input
[1]
Bus
Activates a start command via the serial
communication port or fieldbus option.
[2]
Logic
Activates a start command via the fieldbus/serial
AND
communication port, AND additionally via one
of the digital inputs.
[3]
Logic OR
Activates a start command via the fieldbus/serial
*
communication port OR via one of the digital
inputs.
8-54 Reversing Select
Option:
Function:
[0]
Digital
Select control of the frequency converter
input
reverse function via the terminals (digital input)
and/or via the fieldbus.
[1]
Bus
Activates the reverse command via the serial
communication port or fieldbus option.
[2]
Logic
Activates the reverse command via the
AND
fieldbus/serial communication port, AND
additionally via one of the digital inputs.
[3]
Logic OR
Activates the reverse command via the
*
fieldbus/serial communication port OR via one
of the digital inputs.
8-55 Set-up Select
Option:
Function:
Select control of the frequency converter set-up
selection via the terminals (digital input) and/or
via the fieldbus.
[0]
Digital
Activates the set-up selection via a digital input.
input
[1]
Bus
Activates the set-up selection via the serial
communication port or fieldbus option.
[2]
Logic
Activates the set-up selection via the fieldbus/
AND
serial communication port, AND additionally via
one of the digital inputs.
[3]
Logic OR
Activate the set-up selection via the fieldbus/
*
serial communication port OR via one of the
digital inputs.
MG37G102
Programming Guide
8-56 Preset Reference Select
Option:
[0]
Digital
input
[1]
Bus
[2]
Logic
AND
[3]
Logic OR
*
8-90 Bus Jog 1 Speed
Range:
100 RPM
8-91 Bus Jog 2 Speed
Range:
200 RPM

6.2 9-** and 16-** PROFIBUS Parameters

9-15 PCD Write Configuration
Array [10]
Option:
[0]
[302]
[303]
[312]
[341]
Danfoss A/S © Rev. 05/2014 All rights reserved.
Function:
Select control of the preset reference selection
via the terminals (digital input) and/or via the
fieldbus.
Activates preset reference selection via a digital
input.
Activates preset reference selection via the
serial communication port or fieldbus option.
Activates preset reference selection via the
fieldbus/serial communication port, AND
additionally via one of the digital inputs.
Activates the preset reference selection via the
fieldbus/serial communication port OR via one
of the digital inputs.
Function:
[ 0 - par. 4-13
Enter the jog speed. Activate this
*
RPM]
fixed jog speed via the serial port
or fieldbus option.
Function:
[ 0 - par. 4-13
Enter the jog speed. Activate this
*
RPM]
fixed jog speed via the serial port
or fieldbus option.
None
Minimum Reference
Maximum Reference
Catch up/slow Down Value
Ramp 1 Ramp Up Time
6
Function:
Select the parameters
to be assigned to PCD
3 to 10 of the
telegrams. The number
of available PCDs
depends on the
telegram type. The
values in PCD 3 to 10
are then written to the
selected parameters as
data values. Alterna-
tively, specify a
standard PROFIBUS
telegram in
9-22 Telegram
Selection.
35