Parameters
9-65 Profile Number
Range:
0
[0 - 0 ] This parameter contains the profile identification.
*
NOTICE
This parameter is not visible via LCP.
9-70 Programming Set-up
Option:
[0]
Factory setup Uses default data. This option can be used
6
6
[1]
Set-up 1
[2]
Set-up 2
[3]
Set-up 3
[4]
Set-up 4
[9]
Active Set-up Follows the active set-up selected in
*
This parameter is unique for LCP and fieldbus. See
0-11 Programming Set-up.
9-71 Profibus Save Data Values
Option:
[0]
Off
*
[1]
Store all
setups
[2]
Store all
setups
9-72 ProfibusDriveReset
Option:
[0]
No action
*
[1]
Power-on
reset
[3]
Comm
option
reset
40
Function:
Byte 1 contains the profile number and byte 2 the
version number of the profile.
Function:
Select the set-up to be edited.
as a data source to return the other set-ups
to a known state.
Edits Set-up 1.
Edits Set-up 2.
Edits Set-up 3.
Edits Set-up 4.
0-10 Active Set-up.
Function:
Parameter values changed via PROFIBUS are not
automatically stored in non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
are retained at power-down.
Deactivates the non-volatile storage function.
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0] Off when all parameter values have been
stored.
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0] Off when all parameter values have been
stored.
Function:
Resets frequency converter upon power-up, as
for power-cycle.
Resets the PROFIBUS option only, useful after
changing certain settings in parameter group
9-**, for example, parameter 9-18 Node Address.
Danfoss A/S © Rev. 05/2014 All rights reserved.
Programming Guide
9-72 ProfibusDriveReset
Option:
9-80 Defined Parameters (1)
Array [116]
No LCP access
Read only
Range:
0
[0 - 9999 ] This parameter displays a list of all the defined
*
9-81 Defined Parameters (2)
Array [116]
No LCP access
Read only
Range:
0
[0 - 9999 ] This parameter displays a list of all the defined
*
9-82 Defined Parameters (3)
Array [116]
No LCP access
Read only
Range:
0
[0 - 9999 ] This parameter displays a list of all the defined
*
9-83 Defined Parameters (4)
Array [116]
No LCP access
Read only
Range:
0
[0 - 9999 ] This parameter displays a list of all the defined
*
9-90 Changed Parameters (1)
Array [116]
No LCP access
Read only
Range:
0
[0 - 9999 ] This parameter displays a list of all the
*
Function:
When reset, the frequency converter
disappears from the fieldbus, which may cause
a communication error from the master.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters deviating from
default setting.