Danfoss VLT PROFIBUS DP MCA 101 Programming Manual page 54

Hide thumbs Also See for VLT PROFIBUS DP MCA 101:
Table of Contents

Advertisement

Troubleshooting
Bit (Hex)
00000001
00000002
00000004
00000008
00000010
00000020
00000040
00000080
00000100
00000200
00000400
00000800
00001000
00002000
00004000
00008000
00010000
00020000
8
8
00040000
00080000
00100000
00200000
00400000
00800000
01000000
02000000
04000000
08000000
10000000
20000000
40000000
80000000
Table 8.14 16-92 Warning Word
52
Programming Guide
Dec
Unit
diagnose bit
1
112
2
113
4
114
8
115
16
116
32
117
64
118
128
119
256
104
512
105
1024
106
2048
107
4096
108
8192
109
16384
110
32768
111
65536
96
131072
97
262144
98
524288
99
1048576
100
2097152
101
4194304
102
8388608
103
16777216
88
33554432
89
67108864
90
134217728
91
268435456
92
536870912
93
1073741824
94
2147483648
95
Danfoss A/S © Rev. 05/2014 All rights reserved.
Warning word (16-92 Warning Word)
Brake check
Power card over temperature
Earth fault
Control card
Control word timeout
Over current
Torque limit
Motor thermistor over temp.
Motor ETR over temperature
Inverter overloaded
DC link under-voltage
DC link over-voltage
DC link voltage low
DC link voltage high
Mains phase loss
No motor
Live zero error
10 V low
Brake overload
Brake resistor short circuit
Brake chopper fault
Speed limit
Fieldbus comm. fault
24 V supply fault
Mains failure
Current limit
Low temperature
Voltage limit
Encoder loss
Output frequency limit
Unused
Warning word 2 (ext. stat. word)
Warning word 2
Warning no.
28
29
14
65
18
13
12
11
10
9
8
7
6
5
4
3
2
KTY Warn
1
Fans Warn
26
ECB Warn
25
27
49
34
47
36
59
66
64
61
62
PTC 1 Safe Stop (W71)
-
-
MG37G102

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents