ELECTRICAL SYSTEM
15
SECONDARY FUSES
A – From ignition key to safety logic / starting (15 A).
B – From ignition key to lights, brake lights, horn, turn
signals (15 A).
C – From battery to injection permanent power supply (3 A).
D – From battery to injection (15 A).
E – Free
IMPORTANT Three spare fuses are supplied (3, 15, 15 A).
16
STARTER MOTOR
peak power draw approximately 100 A
17
LAMBDA SENSOR
oxygen sensor with heater
sensor output between 0 and 0.9 V (measured across pins 1
and 2)
heater resistance 12.8 Ω (measured across pins 3 and 4 at
temperature of 20°C – 68°F)
18
VOLTAGE REGULATOR
voltage to measure at battery poles (from 13.5 to 14V with
engine at 4000 rpm depending on load)