3. ERROR INDICATIONS

This machine includes a self-diagnosis function. If the machine does not work normally it
judges that an error has occurred, and indicates the corresponding error message on the
LCD, which in turn helps the service personnel to quickly find out the problem.
3.1 Error Codes
Errors in shaded column do not usually occur during normal use. The possible causes are
noise around the installation site, fluctuation of the power supply voltage, and failures in the
software.
Error
codes
0100
Cannot detect the synchronized signal
of the main motor.
0201
The speed of the main motor does not
stabilize within the specified time.
0202
0203
0204
0205
0206
0207
0208
0209
Cannot detect the lock signal of the polygon
0300
motor for the laser unit (second time).
Cannot detect the lock signal of the polygon
0305
motor for the laser unit (first time).
Cannot detect the synchronized signal
0401
of the polygon motor for the laser unit
(second time).
0402
Cannot detect the synchronized signal of the
0405
polygon motor for the laser unit (first time).
The center thermistor of the fuser unit
0501
has not reached the specified
temperature within the specified time.
The center thermistor of the fuser unit has
not reached the specified temperature
0502
within the specified time after it was
heated normally to the certain level.
The center thermistor of the fuser unit
0503
detected a temperature higher than
the specified value.
Refer
Description
2-26
2-27
2-27
2-27
2-27
2-28
2-28
2-28
2-9
Error
to:
codes
After the heat unit was heated normally, the
0504
center thermistor of the fuser unit detected a
temperature lower than the specified value.
The center thermistor of the fuser unit
detected a temperature rise greater
0505
than the specified value within the
specified time.
The center thermistor of the fuser unit
0506
detected a temperature fall greater than the
specified value within the specified time.
The hardware detected a temperature
050A
error through the center thermistor or
the side thermistor of the fuser unit.
When the center thermistor of the fuser unit
was lower than the idle temperature, the side
050B
thermistor detected a temperature higher
than the specified temperature.
When the center thermistor of the fuser unit
was higher than the idle temperature, the
050C
side thermistor detected a temperature lower
than the specified temperature.
050D ―
050F
An error occurred in the fuser unit.
A communication error occurred
0600
between the ASIC controlled by
engine and the motor driver.
0700
0800
Detected irregular power supply for
0900
more than 100 times.
0A01
0A02
Detected a fan failure.
An error occurred in the high-voltage
0B01
power supply PCB ASSY while operating.
An error occurred in the high-voltage
0B02
power supply PCB ASSY when the
machine was in the ready state.
0C00 ―
0D01 ―
Refer
Description
2-28
2-28
2-29
2-30
2-30
2-30
2-30
2-31
2-31
2-32
2-32
2-32
Confidential