9.9 Top Cover ASSY
(1) Disconnect the panel PCB flat cable from the main PCB ASSY.
(2) Disconnect the new toner sensor PCB flat cable from the panel PCB ASSY.
Note:
• After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
• When connecting flat cables, do not insert them at an angle. After insertion, check
that the cables are not at an angle.
(3) Remove the taptite bind B M4x12 screw.
(4) Release the hooks on the top cover ASSY in order of the hook A to F, and remove the
top cover ASSY in the direction of the arrow.
Panel PCB
flat cable
Taptite bind
B M4x12
Panel PCB
flat cable
Top cover ASSY
Hook E
Main PCB ASSY
Fig. 3-16
New toner sensor PCB flat cable
3-22
Hook F
Hook B
Hook D
Hook C
Panel PCB ASSY
Hook A