Setting Default Paper Size (Led Models) / Setting By Spec (Lcd Models) - Brother HL-L2300D Service Manual

Table of Contents

Advertisement

1.1 Setting Default Paper Size (LED Models) /
Setting by Spec (LCD Models)
<Operating Procedure>
LED models
(1) Copy the "SET_COUNTRYCODE.zip"
file of the relevant model to the
desired location on the computer and
extract it.
(2) Turn OFF the power switch of the
machine and open the front cover.
(3) Press and hold the [Go] key, and turn
ON the power switch. The Toner,
Drum, and Paper LEDs light.
(4) Release the [Go] key. All LEDs go out.
(5) Press and hold the [Go] key more
than two seconds and check that the
Paper LED lights. Release the [Go]
key and close the front cover.
(6) Connect the machine to your
computer using the USB cable.
(7) Open the temporary folder and
double-click "FILEDG32.EXE" to start
it, and select "Brother Maintenance
USB Printer".
(8) Drag and drop the pjl file copied in the
procedure (1) onto the "Brother
Maintenance USB Printer" icon in the
FILED32 screen. The file is loaded to
the machine, and the setting starts.
(9) Wait for approximately five seconds,
and then turn OFF the power switch of
the machine and disconnect the USB
cable.
Note:
• For LCD models, perform settings for a country as described in
(function code: 74)" in Chapter
Please contact Brother distributors for the latest information.
LCD models
(1) Press the [OK] key and then the [Go]
key while the machine is in the ready
state. Then, press the [▲] key four
times to enter the maintenance mode.
(2) Press the [▲] or [▼] key to display
"MAINTENANCE 74" on the LCD, and
press the [OK] key. The country code
currently set is displayed on the LCD.
(The first digit is flashing.)
(3) Press the [▲] key to enter "1", or the
[▼] key to enter "0". Then press the
[OK] key. The second digit starts to
flash.
(4) Press the [▲] key to enter "1", or the
[▼] key to enter "0" similarly. Then
press the [OK] key. The second digit is
completed and the fourth digit starts to
flash.
(5) The third digit and fourth digit changes
at once when the [▲] or [▼] key is
pressed. Press the [Go] key when the
desired value is shown on the screen.
The new setting is saved, and
"PARAMETER INIT" is displayed on
the LCD. The machine then returns to
the initial state of maintenance mode.
5.
4-2
"1.3.15 Setting by spec
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents