Brother HL-L2300D Service Manual page 121

Table of Contents

Advertisement

(3) Remove the screw pan (S/P washer) M3.5x6 screw, and remove the FG harness from
the LVPS shield plate.
(4) Release the LVPS-heater harness and the FG harness from the securing fixtures.
(5) Remove the power cord or the inlet from the mounting position. (For models with inlet*,
remove the taptite flat B M3x10 screw, and remove the inlet*.)
(6) Remove the two taptite cup S M3x8 SR screws, and remove the low-voltage power
supply PCB ASSY. Disconnect the LVPS harness from the back of the low-voltage
power supply PCB ASSY.
LVPS shield plate
LVPS harness
Low-voltage power
supply PCB ASSY
Taptite cup S M3x8 SR
Screw pan (S/P washer) M3.5x6
Taptite cup S M3x8 SR
Harness routing: Refer to
Assembling Note:
• After the replacement, refer to
SUPPLY PCB ASSY" in chapter 4
the low-voltage power supply PCB ASSY.
• Make sure to attach insulation sheet. Failure to attach the insulation sheet can result in
fire or electrical shock.
*
Models with inlet: Germany/U.K./Switzerland/Italy/Israel/Russia/France/Belgium/
FG harness
LVPS-heater harness
Fig. 3-24
"5. Rear side of the
"2. IF YOU REPLACE THE LOW-VOLTAGE POWER
to reset irregular power supply detection counter of
Netherlands/PAN-NORDIC/Iberia/CEE-General/Peru
3-28
Mounting position
Power cord
machine".
<Back side>
Mounting position
Taptite flat B M3x10
Inlet*