Digi-Sense TC9600 Advanced User Manual page 17

Multiparameter temperature controller with thermocouple, thermistor, and rtd inputs
Hide thumbs Also See for TC9600 Advanced:
Table of Contents

Advertisement

ON/OFF Control Mode Setup:
Screen # 4 - Selecting Alarm Setting
Use the UP/DOWN arrow keys to change between
Auto Reset, Manual Reset ,and Off.
Press MENU key to advance to next screen:
- If Auto or Manual is selected, the controller will advance to screen # 5.
- If selection is OFF, the controller will advance to screen # 9.
Screen # 5 - Selecting Alarm Mode
Use the UP/DOWN arrow keys to select alarm mode.
Selectable alarm modes:
- Process High: The alarm will be activated if the
temperature rises above the user set alarm value.
- Process Low: The alarm will be activated if the temperature goes below the
user set alarm value.
- Process High/Low: The alarm will be activated if the temperature goes above or below
the high and low temperature levels set by user.
- Deviation High: Alarm activation point that changes with the change of the process
set point. Example: The user sets deviation high alarm at 30°C and has a process set point of
100°C. If the temperature reaches 130°C, the alarm will be activated. The user changes
process set point to 60°C. If process temperature reaches 90°C, the alarm will be activated.
- Deviation Low: Alarm activation point that changes with the change of the process
set point. Example: User sets the deviation low alarm 30°C and the process set point is 100°C.
If the process temperature is 70°C or less, the alarm will be activated. If the process set point
temperature is set at 70°C, then if the process temperature is 40°C or less, it will activate the
alarm.
- Deviation High/Low: Same as Deviation High and Deviation Low alarms. It has the
capability of having an alarm activate when the set point temperature goes above or
below a set point temperature.
- Deviation Band: Allows the user to set the alarm to be activated within a specified
temperature range.
Press the MENU key to advance to screen # 6 after selecting alarm mode.
1.800.561.8187
17
www.
.com
information@itm.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC9600 Advanced and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Related Products for Digi-Sense TC9600 Advanced

This manual is also suitable for:

89800-1489800-13

Table of Contents