Maintenance; Maintenance And Cleaning The Unit; Troubleshooting - ProLights SOLAR48Q User Manual

Outdoor compact washlight
Table of Contents

Advertisement

- 4 - MAINTENANCE

4.1 MAINTENANCE AND CLEANING THE UNIT

• Make sure the area below the installation place is free from unwanted persons during setup.
• Switch off the unit, unplug the main cable and wait until the unit has cooled down.
• All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
• Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
• When the lens is visibly damaged due to cracks or deep scratches, it must be replaced.
• The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
• In order to protect the device from overheating the cooling fans (if any), and ventilation openings
should be cleaned monthly.
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts
subject to dust and grease deposits. The frequency with which the following operations are to be carried
out depends on various factors, such as the amount of the effects and the quality of the working environ-
ment (air humidity, presence of dust, salinity, etc.). Use a soft cloth dampened with any detergent liquid
for cleaning glass to remove the dirt from the reflectors, from the lenses and filters.
It is recommended that the projector undergoes an annual service by a qualified technician for special
maintenance involving at least the following operations:
-
General cleaning of internal parts..
-
Restoring lubrication of all parts subject to friction, using lubricants specifically.
-
General visual check of the internal components, cabling, mechanical parts, etc.
-
Electrical, photometric and functional checks; eventual repairs.
Warning: we strongly recommend internal cleaning to be carried out by qualified personnel!

4.2 TROUBLESHOOTING

Problems
Fixture does not light up
General low light intensity
Fixture does not power up
Fixture does not respond to DMX
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
SOLAR48Q
Possible causes
No mains supply
Dimmer fader set to 0
All color faders set to 0
Faulty LED
Faulty LED board
Dirty lens assembly
Misaligned lens assembly
No power
Loose or damaged power cord
Faulty internal power supply
Wrong DMX addressing
Damaged DMX cables
Bouncing signals
Checks and remedies
Check the power supply voltage
Increase the value of the dimmer channels
Increase the value of the color channels
Replace the LED board
Replace the LED board
Clean the fixture regularly
Install lens assembly properly
Check for power on power outlet
Check power cord
Replace internal power supply
Check control panel and unit addressing
Check DMX cables
Install terminator as suggested