3.1.4 Checking Wired Controller

Wired Controller Model: CIW01
Each "Check Menu" item and its function are explained in the following table.
Check Menu Item
Check 1
Check 2
Alarm History Display
Model Display
I.U./O.U. PCB Check
Self Checking
l Setting Method
Normal Mode Display
Meeting Room
A/C
MODE
SPEED
COOL
Motion Sensor ON
LOUV.
On/Off
(1) Check 1 and Check 2
(1) Press and hold "Menu" and "ECO" simultaneously
for three seconds during the normal mode.
The Check Menu is displayed.
(2) Select "Check 1" (or "Check 2") from the Check
Menu and press "OK".
(3) Select the Set Indoor Unit by pressing
"
" and press "OK". This screen is NOT
displayed when there is only one indoor unit
connected with the wired controller. In this case,
(4) below is displayed.
(4) Press " " or " " to change the screen.
SM-16005-rev.2
Sensor condition of air conditioner are monitored and indicated.
Sensor data of air conditioner prior to alarm occurrence is indicated.
Previous alarm record (date, time, alarm code) is indicated.
Model name and manufacturing number are indicated.
The result of PCB check is indicated.
Checking of wired controller is carried out.
FLTR
LOUV.
TEMP
Avoid
Adj.
Menu
OK
Back/Help ECO
Function
Check Menu Display
Check Menu
Check 1
Check 2
Alarm History Display
Model Display
Function 5
Sel.
OK
Press and hold "Menu" and "ECO"
simultaneously for three seconds during
the normal mode.
Check Menu
Check 1
Check 2
Alarm History Display
Model Display
Function 5
Sel.
OK
Check 1
01-01
02-01
03-01
01-02
02-02
03-02
01-03
02-03
03-03
01-04
02-04
03-04
Sel.
OK
Check 1:01-03
Item Value
b1
22
b2
20
b3
55
b4
20
b5
25
Next Page
TROUBLESHOOTING
01
/
02
Rtrn
Entr
Back
01
/
02
Rtrn
Entr
Back
04-01
04-02
04-03
04-04
Rtrn
Entr
Back
01
/
07
Rtrn
Back
3-9