5.4.2
Function Setting
5.4.2.1 Function Selection Item
● for Ducted (Medium Static) with EconoFresh Kit
No. Items
Optional Function
Cancellation of Heating
1
b1
Temperature Compensation
due to Uneven Heat Load
Circulator Function during
2
b2
Heating Thermo-OFF
3
b3
Not Prepared
4
b4
Change of Filter Cleaning Time
5
b5
Fixing of Operation Mode
6
b6
Fixing of Setting Temperature
Fixing of Operation as
7
b7
Exclusive Cooling Unit
8
b8
Automatic COOL/HEAT Operation
9
b9
Fixing of Fan Speed
10
bA
Not Prepared
Cooling Temperature Compensation
11
bb
due to Uneven Heat Load
12
bC
Not Prepared
13
bd
Not Prepared
14
bE
Not Prepared
15
C1
Not Prepared
16
C2
Not Prepared
17
C3
Not Prepared
18
C4
Not Prepared
19
C5
EconoFresh Pressure Mode (*8)
Hi Speed during Heating Thermo-
20
C6
OFF
Canceling of Enforced 3 Minutes
21
C7
Minimum Operation Time of
Compressor
22
C8
Thermistor of Wired Controller (*6)
23
C9
Not Prepared
24
CA
Not Prepared
25
Cb
Selection of Forced Stoppage Logic
26
CC
Not Prepared
SM-16005-rev.2
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
Individual
Setting
Setting
Condition
00
Standard (Set Temp. +7
01
Removal (Set Temp.)
02
Set Temp. +3
03
Set Temp. +5
04
Set Temp. +2
00
Not Available
01
Available
-
-
Not Used (Use as 00 conditions)
00
Standard 1,200 hrs (Factory-Setting)
01
100 hrs
-
02
1,200 hrs
03
2,500 hrs
04
No Indication
00
Standard
×
01
Fixed
00
Standard
×
01
Fixed
00
Standard
×
01
Fixed
00
Not Available
×
01
Available
00
Standard
×
01
Fixed
-
-
Not Used
00
Standard (No Compensation)
×
01
Set Temp. –2
02
Set Temp. –3
-
-
Not Used (Use as 00 conditions)
-
-
Not Used (Use as 00 conditions)
-
-
Not Used (Use as 00 conditions)
-
-
Not Used (Use as 00 conditions)
-
-
Not Used
-
-
Not Used
-
-
Not Used
00
Not Available (Factory-Setting)
01
EconoFresh Pressure Mode
02
Not Available
00
Not Available
01
Available
00
Standard
01
Cancellation
00
Not Available
01
Control by Thermistor of Wired Controller
02
Control by Average Value of Indoor Air Inlet
Thermistor and Thermistor of Wired Controller
-
-
Not Used
-
-
Not Used
00
Forced Stoppage Input: A Contact
×
01
Forced Stoppage Input: B Contact
-
-
Not Used (Use as 00 conditions)
Contents
o
o
F (+4
C))
o
o
F (+2
C) (*1)
o
o
F (+3
C)
o
o
F (+1
C)
o
o
F (–1
C)
o
o
F (–2
C)
5-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents